Spectroscopic Probe Monitors Hemorrhagic Shock

By HospiMedica International staff writers
Posted on 02 Sep 2015
Print article
Image: The spatially-resolved NIRS (SR-NIRS) probe (Photo courtesy of  EUSTC).
Image: The spatially-resolved NIRS (SR-NIRS) probe (Photo courtesy of EUSTC).
A novel, noninvasive near-infrared spectroscopy (NIRS) device assesses hemorrhagic shock severity as accurately as a standard blood draw.

Developed by researchers at the University of Electronic Science and Technology of China (EUSTC; Chengdu, China), the portable probe uses spatially-resolved NIRS (SR-NIRS) to measure tissue blood oxygen saturation (StO2). The probe consists of a triple light emitting diode (LED) that emits light at wavelengths of 735, 805 and 850 nanometers, and two detectors. Since the diameter of each individual detector is only about 0.6 cm, it was impossible to arrange them in a linear pattern, and they were therefore placed in the shape of triangle.

The researchers then used an ultrasound to locate the internal jugular central vein to aid in the placement of SR-NIRS probe, which was then fine-tuned and fixed until the signal became stable. In subsequent tests, noninvasive StO2 measurements were highly correlated with central internal jugular central vein oxygenation level (ScvO2), the current gold standard. The researchers concluded that SR-NIRS device can be used at the bedside for continuous monitoring of shock, and could be used as a clinical tool for shock management. The study was published in the September 2015 issue of Biomedical Optics Express.

“The diffuse reflectance and absorption of the near-infrared light in the tissue is particularly effective at measuring hemoglobin levels, and has seen widespread use as a screening tool for intracranial bleeding,” concluded lead author associate professor Ting Li, PhD, of the electronic thin film and integrated device lab at UESTC, adding that “the standard method to monitor shock is invasive, discontinuous, and time-consuming.”

Current technologies for measuring blood oxygen saturation include peripheral capillary oxygen saturation (SpO2) finger scanners, but as the fingertips are at the periphery of the circulatory system, these can give inaccurate readings for patients with reduced circulation. Using a probe placed near the jugular vein in the neck can allow doctors to continuously monitor a patient's recovery from shock without the need to continuously draw and analyze blood, as in ScvO2.

Related Links:

University of Electronic Science and Technology of China


Gold Member
12-Channel ECG
CM1200B
Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Vibrating Mesh Nebulizer
Aerogen Solo

Print article

Channels

Surgical Techniques

view channel
Image: NTT and Olympus have begun the world\'s first joint demonstration experiment of a cloud endoscopy system (Photo courtesy of Olympus)

Cloud Endoscopy System Enables Real-Time Image Processing on the Cloud

Endoscopes, which are flexible tubes inserted into the body's natural openings for internal examination and biopsy collection, are becoming increasingly vital in medical diagnostics. Their minimal invasiveness... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The PATHFAST hs-cTnI-II high-sensitivity troponin assay has been developed for the PATHFAST Biomarker Analyzer (Photo courtesy of Polymedco)

POC Myocardial Infarction Test Delivers Results in 17 Minutes

Chest pain is the second leading cause of emergency department (ED) visits by adults in the United States, generating over 7 million visits annually. In the event of a suspected heart attack, physicians... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.