Stochastic Resonance Enhances Surgeon’s Haptic Sensation

By HospiMedica International staff writers
Posted on 24 Aug 2016
Print article
Image: The PZT Actuator attached to standard surgical forceps (Photo courtesy Yuichi Kurita, Hiroshima University).
Image: The PZT Actuator attached to standard surgical forceps (Photo courtesy Yuichi Kurita, Hiroshima University).
A novel device can be slipped onto any surgical tool to vibrate against a surgeon’s palm, improving the ability to sense the details of a patient’s internal tissues and organs.

The PZT Actuator, developed at Hiroshima University (Japan), is a vibration device that works via the stochastic resonance effect, a mathematical principle that describes how a constant and regular signal can boost the strength of another irregular signal. The device produces vibrations that are so subtle they cannot be sensed; but the constant, uniform vibration of the actuator enhances the surgeon’s sensitivity to other, irregular sensations. As a result, the touching of different tissues with a metal tool, which may normally be too subtle for the surgeon to detect, is boosted to a noticeable level.

In a study to test the device, the lead-zirconate-titanate PZT actuator was placed on the grip of surgical forceps. Volunteers were blindfolded and asked to use the forceps to try and identify different textures of sandpaper, as well as find a small Styrofoam ball inside a cup filled with silicone. The results revealed that the vibration intensity significantly improves sensitivity. The device does not need to be fine-tuned to each user’s unique sense of touch, meaning the PZT Actuator should be robust and simple to use. The study was published on July 14, 2016, in IEEE/ASME Transactions on Mechatronics.

“The PZT Actuator remains safe for patients because the device is only on the handles of the surgeon’s tools, not inside the patient’s body. The vibrations are so subtle that they do not shake the tool. The electrical power supply is also safe for doctors and patients,” said lead author Yuichi Kurita, PhD. “Our next set of experiments will confirm the usefulness of the PZT Actuator in surgical situations. Before we can give this tool to surgeons, we must also develop a method to maintain good hygiene of the device so it is always safe for patients.”

Stochastic resonance boosts any signal by adding a white noise, which contains a wide spectrum of frequencies. The frequencies in the white noise corresponding to the original signal's frequencies will resonate with each other, amplifying the original signal while not amplifying the rest of the white noise, thereby increasing the signal-to-noise ratio, which makes the original signal more prominent. Further, the added white noise is detectable by the sensor, which can then filter it out to effectively detect the original, previously undetectable signal.

Related Links:
Hiroshima University


Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Medical Gas Blender
BlenderBuddy 1

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.