Raman Scattering Helps Evaluate Laser Ablation

By HospiMedica International staff writers
Posted on 25 Feb 2015
Print article
Raman spectroscopy can be used to differentiate squamous cell carcinoma (SCC) from normal skin following treatment with high-powered lasers, according to a new study.

Researchers at Florida Atlantic University (FAU; Boca Raton, USA) obtained 25 tissue samples from 11 patients undergoing Mohs micrographic surgery for the removal of non-melanoma skin cancer (NMSC). Laser treatment was performed using a fractional CO2 laser emitting at 10.6 μm. Treatment levels ranged from 20 mJ to 1200 mJ total energy delivered per laser treatment spot. Raman spectra were collected from both untreated and CO2 laser-treated samples, using a 785 nm diode laser. The researchers then classified spectra as originating from either normal or NMSC tissue, and from treated or untreated tissue.

The results showed that partial laser ablation did not adversely affect the ability of Raman spectroscopy to differentiate normal from cancerous residual tissue, with the spectral classification model correctly identifying SCC tissue with 95% sensitivity and 100% specificity following partial laser ablation, compared with 92% sensitivity and 60% selectivity for untreated NMSC tissue. The main biochemical difference identified between normal and NMSC tissue was high levels of collagen in the normal tissue, which was lacking in the NMSC tissue.

The researchers concluded a Raman-based technique for skin cancer diagnosis and treatment, although not yet fully developed, could one day obviate the need for a more costly and time-consuming treatment method like Mohs micrographic surgery, at least in some, if not all, clinical cases, since CO2 laser treatment does not hinder the ability of Raman spectroscopy to differentiate normal from diseased tissue. The study was published in the December 2014 issue of Lasers in Surgery and Medicine.

“Successful clinical implementation of the proposed surgical method could greatly enhance the speed and effectiveness of skin cancer treatment, especially if real-time analysis of the process were developed,” said lead author associate Professor of Chemistry and Biochemistry Andrew Terentis, PhD, of the FAU Charles E. Schmidt College of Science. “It demonstrates the feasibility of a potentially much faster and more accurate mode of skin cancer treatment based entirely on laser technology.”

Raman spectroscopy is a form of molecular spectroscopy based on Raman scattering. When a beam of light interacts with a material, part of it is transmitted, part it is reflected, and part of it is scattered; over 99% of the scattered radiation has the same frequency as the incident beam, but a small portion has frequencies different from that of the incident beam. This scattered radiation contains information on the particular atoms or ions that comprise the molecule, the chemical bonds connect them, the symmetry of their molecule structure, and the physicochemical environment where they reside.

Related Links:

Florida Atlantic University


Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Neonatal Transport Ventilator
Babylite

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.