Mobile Phone Microscope Aids Malaria Diagnosis

By HospiMedica International staff writers
Posted on 16 Sep 2015
Print article
Image: The MOPID device atached to an iPhone (Photo courtesy Casey of Pirnstill/ TAMU).
Image: The MOPID device atached to an iPhone (Photo courtesy Casey of Pirnstill/ TAMU).
A 3-D printed polarized microscope that can be attached to a mobile phone could help faster malaria detection in areas with limited access to expensive lab facilities and expert technicians.

Developed by researchers at Texas A&M University (TAMU; College Station, TX, USA), the low-cost, lightweight, high quality mobile-optical-polarization imaging device (MOPID) offers 40–100x magnification, sufficient to image pigmentation of the hemozoin crystal, a waste product produced by ‎Plasmodium falciparum, the parasite that causes malaria. To perform the test, a glass slide with a blood smear is inserted into the device; the cell phone camera then takes a picture, and the photo shows the presence (or absence) of malaria.

The MOPID system consists of a commercial Apple iPhone 5S cellular phone, a snap on 3D-printed cartridge with individual compartments that allowed for polarized microscopy, two polarizer sheets, low-power white light emitting diodes (LEDs), and a plastic lens assembly configuration allowing for appropriate magnification, resolution, and field of view (FOV) for diagnosing the presence of the malaria parasite. The analyzer can be rotated to vary the degree of polarization, thus allowing for birefringence measurements from the hemozoin crystal.

The researchers are moving forward to construct a more durable, compact, and cheaper device for in vivo field-testing in Rwanda. They envision that the final product could be available for less than USD 1.00 per test result, not including the cost of the mobile phone attached to the MOPID device. A study describing the system and comparing performance to a Leica Microsystems (Wetzlar, Germany) DMLM polarized white light microscope was published on August 25, 2015, in Nature Scientific Reports.

“Because of the lack of access to lab testing, many health-care providers rely on rapid diagnostic tests, which are the equivalent of a pregnancy test for parasites. They are not always reliable and can lead to misdiagnosis and overtreatment. Giving medicine to those who don’t need it is causing drug-resistant strains of malaria to develop,” said lead author biomedical engineer Casey Pirnstill, BSc. “The device could be used by a nurse or other health outreach workers. The original photos would be saved in case further interpretation by a doctor is required.”

There are more than 200 million new malaria cases yearly, and high-quality microscopy is still the most accurate method for detection of infection. Microscopy, however, requires well-trained personnel and can be very time-consuming. As a result, less than half of the suspected malaria cases in Sub-Saharan Africa in 2012 received a diagnostic test.

Related Links:

Texas A&M University
Leica Microsystems


Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Silver Member
ECG Management System
NEMS-Q

Print article

Channels

Surgical Techniques

view channel
Image: Lightning Flash 2.0 features advanced computer assisted vacuum thrombectomy software (Photo courtesy of Penumbra)

Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots

Pulmonary embolism (PE) occurs when a blood clot blocks one of the arteries in the lungs. Often, these clots originate from the leg or another part of the body, a condition known as deep vein thrombosis,... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.