We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
Sekisui Diagnostics UK Ltd.

Download Mobile App




Unfolding Origami Robot Helps Retrieves Ingested Artifacts

By HospiMedica International staff writers
Posted on 26 May 2016
Print article
Image: The ingestible capsule and the unfolded origami robot (Photo courtesy of Melanie Gonick / MIT).
Image: The ingestible capsule and the unfolded origami robot (Photo courtesy of Melanie Gonick / MIT).
A new study describes how a tiny origami robot steered by external magnetic fields crawled across the stomach wall to remove a swallowed button battery.

Developed by researchers at the Massachusetts Institute of Technology (MIT, Cambridge, MA, USA), the University of Sheffield (United Kingdom), and the Tokyo Institute of Technology (Japan), origami is a functional three-dimensional (3D) robot than can be actuated on-demand for untethered walking and swimming. The rectangular robot has accordion folds perpendicular to its long axis, and pinched corners that act as points of traction.

Structurally, it consists of a heat-sensitive layer sandwiched between two structural layers that form a sheet 1.7 cm3 in size. A pattern of slits in the outer layers determines how the robot will unfold when the middle layer is thermally activated. At the center of one the forward accordion folds is a permanent cubic neodymium magnet that responds to changing magnetic fields outside the body. The forces that control the robot’s motion are principally rotational; a quick rotation will make it spin in place, but a slower rotation will cause it to pivot around one of its fixed feet.

Since the robot has asymmetric body balance along the sagittal axis, it can walk at a speed of 3.8 body-lengths per second while under control of the alternating external magnetic field. The origami robot propels itself using a “stick-slip” motion, in which its appendages stick to a surface through friction when it executes a move, but slip free again when its body flexes to change its weight distribution. The robot is made of a biocompatible, acetone-degradable material that allows the entire robot’s body to vanish in a liquid.

In experiments involving a simulation of the human esophagus and stomach, the robot unfolded itself from an ingestible capsule, and steered by external magnetic fields, crawled across the simulated stomach wall to remove a swallowed button using its cubic neodymium magnet. It then degraded. The origami robot was presented at the International Conference on Robotics and Automation, held during May 2016 in Stockholm (Sweden).

“It’s really exciting to see our small origami robots doing something with potential important applications to health care,” said study presenter Professor Daniela Rus, PhD, director of the MIT Computer Science and Artificial Intelligence Laboratory (CSAIL). “For applications inside the body, we need a small, controllable, untethered robot system. It’s really difficult to control and place a robot inside the body if the robot is attached to a tether.”

Related Links:
Massachusetts Institute of Technology
University of Sheffield
Tokyo Institute of Technology
Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Bronchoscope
EB-500

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.