We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
Sekisui Diagnostics UK Ltd.

Download Mobile App




Bioactive Foam Scaffold Helps Replace Lost Bone

By HospiMedica International staff writers
Posted on 19 Apr 2017
Print article
Image: A novel bioactive shape memory polymer could replace missing bone (Photo courtesy of RPI).
Image: A novel bioactive shape memory polymer could replace missing bone (Photo courtesy of RPI).
Novel malleable bioactive foam can be used to treat craniomaxillofacial osseous gaps in the skull resulting from injury, surgery, or birth defects.

Under development by researchers at the Rensselaer Polytechnic Institute and Texas A&M University, the bioactive foam is based on a shape memory polymer (SMP) made of crosslinked poly(ε-caprolactone) (PCL) diacrylate coated in a bioactive polydopamine. When exposed to warm saline, the foam material becomes pliable, allowing it to be easily shaped to fit irregular defects in the skull.

Subsequent cooling causes the scaffold to lock in its temporary shape within the defect. Once in place, the SMP exhibits an interconnected pore morphology and bioactivity that enhance tissue regeneration, thanks to the polydopamine-coating, which promotes superior bioactivity, osteoblast adhesion and proliferation, osteogenic gene expression, and extracellular matrix (ECM) deposition. The formation of hydroxyapatite naturally regenerates bone that eventually replaces the foam with de-novo bone.

“The approach has a number of advantages, particularly when contrasted with other options under research, such as 3D printing methods,” said professor of biomedical engineering Mariah Hahn, PhD, of RPI. “A moldable bone-promoting scaffold could have broad use if it's successful. It takes advantages of the body's own healing ability, and it's a low-cost, ‘off the shelf’ solution that would not need to be pre-tailored to the individual defect.”

“Rigid bone graft cannot be readily manipulated to fit within the irregularly shaped bone defect. Due to the lack of fit and good contact with neighboring bone tissue, defect healing is compromised. This is like trying to fill in a missing puzzle piece with the wrong piece,” said associate professor of biomedical engineering Melissa Grunlan, PhD, of TAMU. “These bone defects can cause tremendous functional problems and aesthetic issues for individuals, so it was recognized that a better treatment would make a big impact.”

SMPs include foams, scaffolds, meshes, and other polymeric substrates that have the ability to return from a deformed (temporary) state to their original (permanent) shape induced by an external stimulus such as temperature change, an electric or magnetic field, light, or a solution. Similar to polymers in general, SMPs also cover a wide property-range from stable to biodegradable, from soft to hard, and from elastic to rigid, depending on the structural units that constitute the SMP.

Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Video Laryngoscope
SH-VL1

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.