Robotic Platform Precisely Steers Surgical Catheters

By HospiMedica International staff writers
Posted on 05 May 2021
Print article
Image: Christoff Heunis and the ARMM system (Photo courtesy of Christoff Heunis)
Image: Christoff Heunis and the ARMM system (Photo courtesy of Christoff Heunis)
A new study describes how a prototype system uses electromagnetic fields to automatically guide surgical catheters, providing a possible alternative to manual steering.

The Advanced Robotics for Magnetic Manipulation (ARMM) system, developed at the University of Twente (UT; Enschede, The Netherlands), is based on a cored mobile electromagnet attached to a six degree-of-freedom (DoF) collaborative robot manipulator arm that magnetically steers a catheter with submillimeter precision. Guidance is provided via externally-generated electromagnetic fields that generate co-directional, prescribed magnetic fields and forces with independently controlled magnitudes.

Two serial-link manipulators use an interface to communicate with their own embedded controllers in order to execute the movement of the manipulators upon receiving a pose command, expressed as a set of joint velocities. The effective workspace of the system can be approximated by a sphere with a radius of 783 mm; as the coil is positioned outside the human body, the catheter is always located between 50 mm and 200 mm away. The actuated instrument itself is a commercial coronary guide catheter that is gripped between a gear and bearing structure, with a maximum speed of 12 mm/s.

Once the user defines a catheter target at a known offset, the via-points for both the catheter and transducer are calculated from ultrasound images, with the anatomical parts of interest masked and converted to a point-cloud dataset. To sustain proper insertion control, the catheter tip is tracked via an ultrasound- based matching algorithm. In a phantom model, autonomous catheter insertion achieved a 100% success rate, with an average error between the tracked catheter tip and target positions of 2.09 mm, and a median procedure time of 32.6 seconds.

“I believe that by having an ARMM platform in every hospital, we can transform diagnostic and therapeutic catheterizations. We now just have to work towards clinical trials and advance it from this translational stage,” said ARMM developer Christoff Heunis, MSc, who developed the system as part of his PhD thesis.

A typical endovascular intervention would involve the insertion of a catheter in the groin to access the heart or important arterial branches. The catheter is, in most cases, tracked by utilizing X-ray imaging facilitated by the injection of contrast material, which discriminates the catheter from the arterial tree. Despite its convenience, X-ray imaging causes additional safety risks due to the prolonged exposure of both patients and clinicians to ionizing radiation.

Related Links:
University of Twente

Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Medical Gas Blender
BlenderBuddy 1

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.