POC MRI Helps Evaluate Intracerebral Hemorrhage

By HospiMedica International staff writers
Posted on 09 Sep 2021
Print article
Image: The Swoop low-field pMRI device (Photo courtesy of HyperFine Research)
Image: The Swoop low-field pMRI device (Photo courtesy of HyperFine Research)
A new study confirms that portable magnetic resonance imaging (pMRI) can scan for intracerebral hemorrhage (ICH) at the point-of-care (POC).

Researchers at Yale School of Medicine (New Haven, CT, USA) and Yale New Haven Hospital (YNHH; CT, USA) conducted a study involving 144 pMRI examinations (56 ICH, 48 acute ischemic stroke, 40 healthy controls) taken at the bedside at YNHH from July 2018 to November 2020, and compared them to traditional neuroimaging scans (non-contrast computerized tomography (CT) or 1.5/3 T MRI) to examine the efficacy of the Hyperfine Research (Guilford, CT, USA) Swoop low-field (0.064 T) pMRI device.

Two neuroradiologists evaluated all pMRI scans, with one ICH imaging core lab researcher reviewing the cases of disagreement. The raters correctly detected ICH in 45 of 56 cases (80.4%), and blood-negative cases were correctly identified in 85 of 88 cases (96.6%). Manually segmented hematoma volumes and ABC/2 formula for estimated volumes on pMRI correlated with conventional imaging volumes. Hematoma volumes measured on pMRI at discharge also correlated with manual and ABC/2 volumes. The study was published on August 25, 2021, in Nature Communications.

“There is no question this device can help save lives in resource-limited settings, such as rural hospitals or developing countries,” said senior author professor of neurology and neurosurgery Kevin Sheth, MD, of Yale School of Medicine. “There is also now a path to see how it can help in modern settings. It is of critical importance to continue to collect more data across a range of stroke characteristics so that we can maximize the potential benefit of this approach.”

The Swoop pMRI is a low-field system that features standard permanent magnets that require no power or cooling systems, producing an image using low-power radio waves and magnetic fields instead. The Swoop is controlled via a tablet device, using sequences and protocols selected from a playlist. As a result, the system is 10X lower in weight than current fixed conventional MRI systems, costs a fraction of the price, is highly portable, and plugs directly into a standard electrical wall outlet, with 35X lower power consumption.

Related Links:
Yale School of Medicine
Yale New Haven Hospital
Hyperfine Research


Gold Member
12-Channel ECG
CM1200B
Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Infant Blood Draw Station
Infant Blood Draw Station

Print article

Channels

Surgical Techniques

view channel
Image: Computational models can predict future structural integrity of a child’s heart valves (Photo courtesy of 123RF)

Computational Models Predict Heart Valve Leakage in Children

Hypoplastic left heart syndrome is a serious birth defect in which the left side of a baby’s heart is underdeveloped and ineffective at pumping blood, forcing the right side to handle the circulation to... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more