We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us

Download Mobile App




Surgical Method Could Be Game Changer for Patients with Degenerative Cervical Spine Disease

By HospiMedica International staff writers
Posted on 22 Apr 2022
Print article
Image: Researchers have developed a new surgical method for neck surgery (Photo courtesy of Florida Atlantic University)
Image: Researchers have developed a new surgical method for neck surgery (Photo courtesy of Florida Atlantic University)

Anterior cervical discectomy and fusion (ACDF) is a common type of neck surgery that involves removing a damaged disc to relieve pressure on the spinal cord or nerve root and thereby alleviate associated pain, numbness, weakness or tingling. The damaged disc is removed from between two vertebral bones along with simultaneous fusion surgery. The fusion involves placing a bone graft or “cage” and/or implants where the disc was originally located to stabilize and strengthen the area. The use of cages for ACDF is important postoperatively to the alignment of the cervical spine and to maintain the intervertebral disc height. Few studies, however, have examined the impact of the underlying cancellous or “spongy” bone contact with regards to handling large loads from the cage. Moreover, it is still not clear whether a cage with or without screws will be the best choice for long-term fusion as the micromotion or sliding distance and subsidence or penetration of the cage still take place repeatedly. Now, for the first time, researchers have evaluated the effect of the range of motion, cage migration and subsidence using variable angle screws.

For the study, the researchers at Florida Atlantic University (Boca Raton, FL, USA) developed five finite element models from a cervical spine model. The first model was an intact spine model, and the second model was an altered model with cage insertion and a 2-level static plate. The other three models were altered models with the same cage insertion and a 2-level dynamic plate. They compared ACDF cages with and without screws on the biomechanical characteristics of the human spine, implanted cage, and associated hardware by comparing the micro motion and subsidence. Results of the study showed that the cage-screw and anterior plating combination model has promising potential to reduce the risk of micro motion and subsidence of implanted cages in two or more level ACDFs. This method could increase the stiffness of the construct and reduce the incidence of clinical and fusion failure following ACDF, which in turn, could decrease the need for revision surgeries or supplemental posterior realignment.

According to the researchers, because of the biomechanical stability of the current construct, there has been no need for a rigid cervical collar, which is typically used by other surgeons. A lower screw rotational angle resulted in superior biomechanical performance and lower incidence of migration and subsidence compared with a higher rotational angle in multilevel applications, regardless of loading. The researchers believe the underlying mechanism may be due to the cage-screw bonded to the bone and the constrained bottom of C5 vertebra making it more rigid. Researchers demonstrated that the cage-screw was able to prevent subsidence in all loading scenarios better than the cage without screws.

“Anterior cervical discectomy and fusion is widely used to treat patients with spinal disorders, where the cage is a critical component to achieve satisfactory fusion results. The risk factors for cage migration are multifactorial and include patient factors, radiological characteristics, surgical techniques and postoperative factors,” said Frank Vrionis, M.D., senior author of the study and director of the Marcus Neuroscience Institute. “Our results showed that the plate used in our study provided directional stability and obtained excellent fusion, indicating promising clinical outcomes for patients with degenerative cervical spine disease.”

“Our research aims to develop a platform for next generation patient-specific spine surgery by combining intelligent image process, AI technology/machine learning, finite element simulation and 3D printing to help surgeons design a surgery plan for each patient,” added Chi-Tay Tsai, Ph.D., study co-author and a professor, FAU Department of Ocean and Mechanical Engineering , and director, FAU Spine Biomechanical Laboratory. “Our clinical and biomechanical data have shown that the outcomes with the rigid static plate are very good. The main reason may be due to greater contact area between the cortical and cancellous bone in the cage-screw than that in unanchored cage constructs.”

Related Links:
Florida Atlantic University 

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Color Doppler Ultrasound System
KC20

Print article

Channels

Critical Care

view channel
Image: The permeable wearable electronics developed for long-term biosignal monitoring (Photo courtesy of CityUHK)

Super Permeable Wearable Electronics Enable Long-Term Biosignal Monitoring

Wearable electronics have become integral to enhancing health and fitness by offering continuous tracking of physiological signals over extended periods. This monitoring is crucial for understanding an... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The PATHFAST hs-cTnI-II high-sensitivity troponin assay has been developed for the PATHFAST Biomarker Analyzer (Photo courtesy of Polymedco)

POC Myocardial Infarction Test Delivers Results in 17 Minutes

Chest pain is the second leading cause of emergency department (ED) visits by adults in the United States, generating over 7 million visits annually. In the event of a suspected heart attack, physicians... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.