Robot-Assisted Needle Positioning in CT-Guided Procedures Improves Accuracy

By HospiMedica International staff writers
Posted on 07 Mar 2023
Print article
Image: The ANT-C system uses CT-scan images to automate needle path planning and needle targeting (Photo courtesy of NDR Medical)
Image: The ANT-C system uses CT-scan images to automate needle path planning and needle targeting (Photo courtesy of NDR Medical)

Percutaneous image-guided needle interventions are generally performed for diagnostic and therapeutic purposes, such as biopsies and ablations. In such procedures, the interventional radiologist (IR) usually performs a freehand needle positioning using imaging modalities, such as ultrasound, magnetic resonance imaging, or computed tomography (CT). It can be challenging to achieve accurate needle positioning, especially in out-of-plane approaches. Over the past decades, robots have been developed to improve the precision of needle positioning. To improve needle positioning accuracy, robotic systems have been developed over the past few decades. For their effective application in clinical practice, these robotic systems must support a wide range of entry points and needle path angles that allow for optimal trajectory choices. In addition to accurate needle positioning, robotic systems may also offer the potential for reduced radiation exposure and shorter procedure times, irrespective of the practitioner's experience. Now, a new study has found that robotic assistance for needle positioning during CT-guided biopsy increases accuracy without increasing procedure times.

During procedures requiring needle positioning, robot assistance results in fewer adjustments in comparison to freehand techniques, even for seasoned interventional radiologists, according to the findings of a study by researchers at Radboud University Medical Center (Nijmegen, The Netherlands). For this study, the researchers used NDR Medical Technology’s (Singapore) ANT-C system that is designed to plan needle trajectory and orient physicians to insert needles manually with great accuracy. ANT-C is not a floor-mounted system, allowing it to be used with any CT scanner, and can also help position multiple needles based on just one scan.

Experts utilized an abdominal phantom to compare robot-assisted needle placements with those executed by an interventional radiology fellow and an experienced interventional radiologist. The analysis involved a total of 12 positionings. According to the results, the robot system significantly improved the number of successful needle targets (20/24 vs. 14/24), while providing greater precision, requiring fewer adjustments in contrast to freehand positioning. There was no significant difference in procedure times between the two methods (19.5 ± 9.2 minutes with robotic assistance vs. 21.0 ± 6.9 minutes freehand). Although the fellow experienced more significant benefits from the assistance, both providers' performance showed improvement with the use of the robotic system.

The researchers acknowledge that the ANT-C system is technically feasible and provides potential for use in clinical settings. However, more research is required to assess whether robotic assistance can improve outcomes and its impact on radiation dose in human patients. While there is a high likelihood that robot assistance can enhance accuracy, speed up procedures and lower radiation exposure, other factors need to be evaluated before its implementation. Factors such as installation, sterilization, and costs can vary widely based on the type of system used. Therefore, the researchers have emphasized the importance of evaluating these adjunct factors.

Related Links:
Radboud University Medical Center
NDR Medical Technology

Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Ceiling-Mounted Digital Radiography System
Radiography 5000 C

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.