We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us

Download Mobile App




First-of-Its-Kind Electronic Skin Patch Enables Advanced Health Care Monitoring

By HospiMedica International staff writers
Posted on 31 Jan 2023
Print article
Image: The advanced electronic skin could enable multiplex healthcare monitoring (Photo courtesy of Terasaki Institute)
Image: The advanced electronic skin could enable multiplex healthcare monitoring (Photo courtesy of Terasaki Institute)

For some time now, electronic skin (E-skin) patches have been used to monitor bodily physiological and chemical indicators of health. Such monitors, placed on the skin, are capable of measuring various parameters like body motions and temperature, skin hydration, different metabolic biomarkers, and brain and heart functionality (via electrocardiograms and electroencephalograms). A skin-sensing patch usually consists of a sensor layer, which converts physical information into electrical signals, positioned on top of a flexible, stretchable substrate layer that rests on the skin and is resistant to mechanical deformation. However, most current substrates have mechanical and biological incompatibilities along with poor breathability, thereby hampering multi-sensing ability and resulting in skin irritation and inflammation, particularly after long-term use. Additionally, most current substrates cannot be recycled or disposed off in an environmentally friendly manner.

Now, scientists from the Terasaki Institute (Los Angeles, CA, USA) have addressed these problems by using a novel gelatin-based, highly porous substrate to devise a first-of-its-kind E-skin patch for advanced healthcare monitoring. Using an optimum choice in materials and a novel fabrication method, the E-skin patch provides simultaneous, continuous monitoring of multiple bodily parameters, along with providing temperature-moisture management and breathability. By opting for gelatin methacryloyl (GelMA) to fabricate their substrate, the researchers managed to meet the need for biocompatibility, biodegradation, self-adhesion, and tissue-like mechanical properties.

However, the need for breathability and moisture control still posed a challenge. It was possible to achieve permeability in GelMA by rendering it into a porous aerogel form, although the resultant aerogel was brittle, making it unsuitable for skin-sensing substrates. The TIBI researchers resolved this issue by carefully examining the effects of cryofreezing on GelMA flexibility and using their understanding to develop a novel method for overcoming the brittleness of GelMA aerogels. Their method led to the creation of a GelMA aerogel that is flexible, breathable, ultralight, and moisture/air-permeable, on account of its highly uniform and interconnected pores and their potential for three-dimensional capillary action. The substrate’s enhanced capabilities also allowed the researchers to screen-print integrated multifunctional sensors onto the substrate, which could then be placed on the skin to simultaneously stimulate sweat excretion and extraction of interstitial fluid just below the surface of the skin. This enables continuous and multifunctional monitoring of bodily parameters like skin temperature and hydration levels, electro-cardiac measurements, and metabolic markers such as glucose, alcohol, and lactic acid.

The researchers validated these functions by using the new E-skin patch in a series of tests measuring the effects of glucose and alcohol-containing diets on subjects performing strenuous exercise. A comparison of the results against various individual commercial measurement devices showed that there was a good correlation. The researchers conducted further tests that validated the new E-skin’s superior flexibility, thermal cooling abilities, and fluid absorption over conventional brittle aerogel substrates, and also demonstrated excellent biocompatibility and biodegradation without any skin irritation. Additionally, the E-skin is biodegradable, thus eliminating the need for environmentally harmful waste disposal. Such an innovative multi-sensing device can provide a more accurate, real-time patient physiological profile. It will also be particularly beneficial for patients having several interrelated health conditions, like those with insulin-dependent diabetes who are prone to severe effects from glucose and alcohol and need to closely monitor their consumption. The E-skin can also find other applications by using different approaches, such as integrating additional simultaneous physiological measurements, coupling with drug delivery systems for therapeutic indications, and incorporating a wireless system for increasing convenience for patients.

“The advancements described here pave the way for producing next-generation electronic skin devices,” said Ali Khademhosseini, Ph.D., TIBI’s Director, and CEO. “They will be valuable tools in healthcare management, offering the best in accurate, real-time monitoring for real-life situations.”

Related Links:
Terasaki Institute

Gold Member
12-Channel ECG
CM1200B
Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Medical Gas Blender
BlenderBuddy 1

Print article

Channels

Surgical Techniques

view channel
Image: The living replacement knee will be tested in clinical trials within five years (Photo courtesy of ARPA-H)

Living Knee Replacement to Revolutionize Osteoarthritis Treatment

Osteoarthritis is the most prevalent type of arthritis, characterized by the progressive deterioration of cartilage, or the protective tissue covering the bone ends, resulting in pain, stiffness, and impaired... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The new eye-safe laser technology can diagnose traumatic brain injury (Photo courtesy of 123RF)

Novel Diagnostic Hand-Held Device Detects Known Biomarkers for Traumatic Brain Injury

The growing need for prompt and efficient diagnosis of traumatic brain injury (TBI), a major cause of mortality globally, has spurred the development of innovative diagnostic technologies.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.