We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
Sekisui Diagnostics UK Ltd.

Download Mobile App




Simplified Bladder Measurement Identifies Postoperative Urinary Retention

By HospiMedica International staff writers
Posted on 17 Feb 2015
Print article
A simple ultrasound (US) test can accurately diagnose the common problem of postoperative urinary retention (POUR), according to a new study.

Researchers at Lapeyronie University Hospital (Montpelier, France) conducted a study to determine whether a simplified US measurement of just the largest transverse diameter of the bladder could be used to diagnose urinary retention. One hundred patients at risk for POUR following orthopedic surgery were evaluated in the postanesthesia care unit before discharge. Bladder diameter was first measured using a portable ultrasound device; an automated evaluation of bladder volume was then performed. Finally, when bladder catheterization was performed, the actual urinary volume was measured (in 49 patients).

The researchers examined correlations between bladder volumes and diameter with receiver operating characteristic curves constructed to determine performance in predicting a bladder volume of over 600 mL. They found a significant correlation between the largest transverse diameter and urinary volumes, as assessed by the other two methods. The average bladder diameter was about 11 cm in patients with POUR, compared with 8–9 cm in those without POUR. The researchers determined that if the bladder diameter was 9.7 cm or less, the patient could be safely discharged.

If the diameter was larger than 10.7 cm, POUR might be present and catheter placement should be considered. The US test would be considered inconclusive only for patients in the "grey zone," i.e., between 9.7 and 10.7 cm. According to the researchers, the simplified measurement method could replace expensive bladder volume measuring devices or more complex US procedures involving the measurement of bladder diameters in three axial dimensions. The study was published on January 30, 2015, in Anesthesia & Analgesia.

“The findings of this study directly call into question the usefulness of expensive specific devices for assessing POUR in the postoperative period,” concluded lead author Aurélien Daurat, MD, and colleagues of the department of anesthesia and critical care medicine. “The test can be efficiently performed by nurses using a widely available portable ultrasound device, an important advantage over approaches using more complex measurements or specialized equipment.”

POUR is defined as the inability to void with a full bladder. The incidence of urinary retention after anesthesia and surgery ranges between 5% and 70%, depending on the type of surgery and the criteria used to define urinary retention. For the patient, retention of urine is painful and requires decompression of the urinary bladder using an intermittent or indwelling urethral catheter, although suprapubic catheterization may be considered if there is urethral trauma or stenosis. A problem arises, however, since catheterization is associated with risks, and an estimated 80% of hospital-acquired urinary tract infections are caused by indwelling urethral catheters.

Related Links:

Lapeyronie University Hospital


Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
EEG System
BRAIN QUICK

Print article

Channels

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.