Simplified Bladder Measurement Identifies Postoperative Urinary Retention

By HospiMedica International staff writers
Posted on 17 Feb 2015
Print article
A simple ultrasound (US) test can accurately diagnose the common problem of postoperative urinary retention (POUR), according to a new study.

Researchers at Lapeyronie University Hospital (Montpelier, France) conducted a study to determine whether a simplified US measurement of just the largest transverse diameter of the bladder could be used to diagnose urinary retention. One hundred patients at risk for POUR following orthopedic surgery were evaluated in the postanesthesia care unit before discharge. Bladder diameter was first measured using a portable ultrasound device; an automated evaluation of bladder volume was then performed. Finally, when bladder catheterization was performed, the actual urinary volume was measured (in 49 patients).

The researchers examined correlations between bladder volumes and diameter with receiver operating characteristic curves constructed to determine performance in predicting a bladder volume of over 600 mL. They found a significant correlation between the largest transverse diameter and urinary volumes, as assessed by the other two methods. The average bladder diameter was about 11 cm in patients with POUR, compared with 8–9 cm in those without POUR. The researchers determined that if the bladder diameter was 9.7 cm or less, the patient could be safely discharged.

If the diameter was larger than 10.7 cm, POUR might be present and catheter placement should be considered. The US test would be considered inconclusive only for patients in the "grey zone," i.e., between 9.7 and 10.7 cm. According to the researchers, the simplified measurement method could replace expensive bladder volume measuring devices or more complex US procedures involving the measurement of bladder diameters in three axial dimensions. The study was published on January 30, 2015, in Anesthesia & Analgesia.

“The findings of this study directly call into question the usefulness of expensive specific devices for assessing POUR in the postoperative period,” concluded lead author Aurélien Daurat, MD, and colleagues of the department of anesthesia and critical care medicine. “The test can be efficiently performed by nurses using a widely available portable ultrasound device, an important advantage over approaches using more complex measurements or specialized equipment.”

POUR is defined as the inability to void with a full bladder. The incidence of urinary retention after anesthesia and surgery ranges between 5% and 70%, depending on the type of surgery and the criteria used to define urinary retention. For the patient, retention of urine is painful and requires decompression of the urinary bladder using an intermittent or indwelling urethral catheter, although suprapubic catheterization may be considered if there is urethral trauma or stenosis. A problem arises, however, since catheterization is associated with risks, and an estimated 80% of hospital-acquired urinary tract infections are caused by indwelling urethral catheters.

Related Links:

Lapeyronie University Hospital


Gold Member
12-Channel ECG
CM1200B
Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Acute Care Scale
PH-740

Print article

Channels

Critical Care

view channel
Image: The stretchable microneedle electrode arrays (Photo courtesy of Zhao Research Group)

Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment

The field of personalized medicine is transforming rapidly, with advancements like wearable devices and home testing kits making it increasingly easy to monitor a wide range of health metrics, from heart... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.