We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Hyper-SAGE Technology Boosts Remote MRI Sensitivity

By HospiMedica International staff writers
Posted on 02 Nov 2009
A new magnetic resonance imaging (MRI) technique, called hyper-SAGE (signal amplification by gas extraction), has the potential to detect ultra-low concentrations of clinical targets, such as lung and other cancers. More...


Development of hyper-SAGE technology was led by one of the world's leading authorities on MRI technology, Dr. Alexander Pines, a chemist who holds joint appointments with the Lawrence Berkeley U.S. National Laboratory (Berkeley Lab; Livermore, CA, USA) and the University of California, Berkeley (USA). The key to this technique is xenon gas that has been bombarded with laser light to "hyperpolarize” the spins of its atomic nuclei so that most are pointing in the same direction.

"By detecting the MRI signal of dissolved hyperpolarized xenon after the xenon has been extracted back into the gas phase, we can boost the signal's strength up to 10,000 times,” Dr. Pines said. "It is absolutely amazing because we're looking at pure gas and can reconstruct the whole image of our target. With this degree of sensitivity, Hyper-SAGE becomes a highly promising tool for in vivo diagnostics [IVD] and molecular imaging.”

MRI is a painless and radiation-free means of obtaining high quality three-dimensional (3D) tomographic images of internal tissue and organs. It is particularly valuable for optically opaque samples, such as blood. However, the application of MRI to biomedical samples has been limited by sensitivity issues. For the past three decades, Dr. Pines has led an ongoing effort to find ways of enhancing the sensitivity of MRI and its sister technology, nuclear magnetic resonance (NMR) spectroscopy. Hyper-SAGE, the latest development, represents a significant new advance for both technologies, according to Dr. Xin Zhou, a member of Dr. Pines' research group.

"Hyper-SAGE is a totally novel way to amplify a solvated xenon MRI/NMR signal in that instead of a chemical process, which is what previous signal enhancement techniques relied upon, it is a physical process,” said Dr. Zhou. "Because gas can be physically compressed, the density of information-carrying polarized gas in our detection chamber can be much greater than the density of an information-carrying solution. This means we can detect MRI signals from concentrations of molecules many thousands of times smaller than can be detected with conventional MRI.”

Dr. Zhou is the first author on an article available online in October 2009 in the Proceedings of the [U.S.] National Academy of Sciences (PNAS). The great contradiction about MRI/NMR spectroscopy is that for being two of the most powerful tools available today for studying the chemical composition and structure of a sample, they are based on an incredible weak signal. Both depend upon atomic nuclei that have an unpaired proton or neutron. Such nuclei spin on an axis similar to miniature tops, giving rise to a magnetic moment--meaning the nuclei act like magnets with a north and south pole. When exposed to an external magnetic field, these spinning "bar magnets” attempt to align their axes along the lines of magnetic force. Since the alignment is not exact, the result is a wobbling rotation, or "precession,” that is unique to each type of atom.

If, while exposed to the magnetic field, the precessing nuclei are also hit with a radiofrequency (RF) pulse, they will absorb and reemit energy at specific frequencies according to their rate of precession (NMR). When the RF pulse is combined with magnetic field gradients a spatially encoded signal is produced, which can be detected and translated into three-dimensional images (MRI).

Obtaining an MRI signal from a sample depends upon the spins of its precessing nuclei being polarized so that an excess point either "up” or "down.” MRI's intrinsic weakness stems from the fact that the natural excess of up versus down spins for any typical population of atomic nuclei in a sample is only approximately one in 100,000. For this reason, traditional MRI techniques are designed to detect nuclei that are highly abundant in tissue, typically the protons in water. Moreover, clinicians use contrasting agents to induce detectable changes in the MRI signal from a sample that can reveal the presence of anomalies. However, the sensitivity is usually too low for molecular imaging, which is needed in cancer detection, for example, where the earliest detections generally produce the most favorable outcomes.

Dr. Pines and his research group have developed numerous ways of increasing the sensitivity of MRI technology and expanding its applicability. Earlier research demonstrated that xenon, an inert gas whose nuclei naturally feature a tiny degree of spin polarization, can be hyperpolarized with laser light to produce a population of xenon atoms in which nearly five out of every 10 nuclei--instead of one out of every 100,000--- produce an MRI signal. The investigators also showed that xenon can be incorporated into a biosensor and linked to specific proteins or other biologic molecules to generated spatial images of a chosen molecular or cellular target.

The new technique, Hyper-SAGE, offers other major advantages over conventional MRI/NMR techniques in addition to a signal that is up to 10,000 times stronger than previous signals, according to Dr. Zhou. "Xenon gas has an intrinsically long relaxation time, greater than 45 minutes, which means the signal lasts long enough for us to collect all the encoded information, which in turn can enable us to detect specific targets, such as cancer-related proteins, at micromolar or parts per million concentrations,” he stated. "Also, Hyper-SAGE utilizes remote detection, meaning the signal encoding and detection processes are physically separated and carried out independently. This is a plus for imaging the lung, for example, where the signal of interest would occupy only a small portion of the traditional MRI signal receiver.”

In their PNAS article, Drs. Zhou, Graziani, and Pines describe the successful testing of the Hyper-SAGE technique on a pair of membranes that mimicked the function of the lungs. Hyperpolarized xenon was dissolved in solution in one membrane to mimic inhalation, and was then extracted as a gas for detection from the other membrane to represent exhalation.

Explained Dr. Zhou, "In a clinical setting, a patient would inhale the hyperpolarized xenon gas which would be dissolved in the blood and allowed to flow into the body and brain. The exhaled xenon gas would then be collected and its MRI signal would be detected. Used in combination with a target-specific xenon biomolecular sensor, we should be able to study the gas-exchange in the lung and detect cancerous cells at their earliest stage of development.”

Berkeley Lab is a U.S. Department of Energy national laboratory located in Berkeley, California. It conducts unclassified scientific research for Department of Energy's (DOE) Office of Science and is managed by the University of California.

Related Links:
Lawrence Berkeley National Laboratory
University of California, Berkeley



Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Digital Radiography System (Ceiling Free)
Digix CF Series
Syringe Pump
SP50 Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: Masimo smartSET pulse oximetry with PPG AFib and OIRD Detection (Photo courtesy of Masimo)

Smart Pulse Oximetry Supports Earlier Recognition of Arrhythmias and Respiratory Risk

On general care floors, respiratory compromise and arrhythmias can develop between routine checks. Atrial fibrillation often goes undiagnosed in older adults, while opioid-induced respiratory depression... Read more

Patient Care

view channel
Image: Researchers evaluated the Omni 128 cm long-axial field-of-view PET/CT system, which captures more of the body and radiotracer signal at once, potentially enabling shorter scans. (Photo courtesy of GE HealthCare)

Total-Body PET/CT Scanner Enables One-Minute Diagnostic-Quality Cancer Imaging

Positron emission tomography/computed tomography (PET/CT) combines radiotracer-based functional imaging with anatomical detail to diagnose, stage, and monitor cancer. Conventional scanners image the body... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: Steris is expanding its healthcare consumables portfolio through an agreement to acquire Xodus Medical, a surgical products business focused on patient and operating room staff safety.

Steris to Expand Surgical Safety Portfolio With $2.1 Billion Xodus Medical Deal

Steris has signed a definitive agreement to acquire Xodus Medical, a specialty surgical products business based in Pennsylvania, for $2.1 billion at closing. The acquisition will expand Steris’s healthcare... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.