Three studies reported that using bone suppression and computer-aided detection (CAD) software can significantly improve the detection of lung nodules on chest X-ray images. More...


CAD performed well on images captured by both portable and upright X-ray machines in the studies, and that most false-positive marks—the marking of portions on the chest X-ray that are not lung nodules—call radiologists’ attention to other significant abnormalities, including serious lung disorders, and to medical devices in or on the chest that radiologists would be able to swiftly disregard. The studies’ findings were presented Radiological Society of North America (RSNA) annual meeting held November 2012 in Chicago (IL, USA). Riverain Technologies’ ClearRead software was used in each of the studies.

Riverain’s ClearRead software suppresses the ribs and clavicles on traditional chest X-ray images, providing radiologists with a clear, unobstructed image of the lungs and exposing abnormalities that may be a sign of disease. The software is easy to install and adopt, requiring no additional imaging equipment or staffing, and no additional radiation exposure to patients. It can be used to immediately enhance images generated by all X-ray machines throughout a hospital or health system.

In a study at Radbound University Nijmegen Medical Center (RUNMC; The Netherlands), five attending radiologists and three radiology residents who were not skilled with the Riverain Technologies (Dayton, OH, USA) software detected more confirmed lung nodules utilizing ClearRead bone suppression 2.4 software than when they evaluated the X-ray images on their own.

The radiologists read 300 chest X-ray images with and without bone suppression (111 X-rays with solitary lung nodules and 189 control cases with no nodules). They identified 79% of the lung nodules with bone suppression, with about 0.3 false positive per image compared to 71% detection of lung nodules and 0.21 false positive per image when they reviewed the X-rays on their own.

“The detection of hard-to-find nodules classified as ‘moderately subtle’ and ‘subtle’ was especially improved,” said Steven Schalekamp, MD, a PhD student in the department of radiology of RUNMC. “The radiologists using the bone-suppression software found 26% of the lung nodules that were missed entirely on conventional X-ray images.”

In a separate RUNMC study involving 300 radiographs and eight readers, the radiologists’ performance also improved when they read the images using Riverain’s CAD software, ClearRead +Detect 5.2, which circles suspected lung nodules on bone-suppressed X-ray images. The radiologists accurately detected 79% of 111 lung nodules with CAD, versus 73% when reviewing the bone-suppressed image without CAD.

The radiologists’ false-positive rate per image was 0.28 when they used CAD and bone suppression combined, and 0.23 when they used bone suppression without CAD. ClearRead +Detect found more than half of the nodules that were missed by the radiologists.
In a University of Chicago Medical Center (IL, USA) study of 608 unselected, consecutive chest X-ray images, (479 X-rays with abnormalities, such as lung nodules, other lung diseases and scars; and 129 X-rays without significant abnormalities), Riverain’s ClearRead +Detect 5.2 CAD software on its own, without radiologist interpretation, detected 72% of lung nodules present, or 82 of 114 nodules. The software detected a majority of the nodules regardless of whether the image had been captured using a portable or upright X-ray machine, and even when other abnormalities, including underlying lung disease, were present.

“CAD found the majority of lung nodules in this large study, which simulates a real-world, clinical setting where the use of portable X-ray images and the presence of other abnormalities in patients’ chests make lung nodule detection challenging,” said Steve Worrell, Riverain’s chief technology officer.

The CAD software had 1.3 false-positives per image (0.7 on X-rays without significant abnormalities and 1.5 on images with abnormalities). Forty-one percent of the false-positives across all radiographs indicated other notable pathologic changes, including fluid in the lungs (edema), pneumonia, a partial or full collapse of a lung (atelectasis), other lung diseases, calcifications, and scars.

Nineteen percent of the false-positive marks were attributed to medical devices in or on the chest, including electrocardiogram leads and catheter ports. As Dr. Schalekamp’s study suggests, the number of false positives actually reported in a clinical environment would be lower because radiologists use their judgment to rapidly reject automatically generated marks that are caused by grossly abnormal tissue or medical devices.

“We expect that after a learning period, radiologists would be able to dismiss false-positive CAD marks very quickly,” Dr. MacMahon said. “We know that small cancers are often visible in retrospect but were not detected on earlier X-rays,” Dr. MacMahon added. “Routine use of bone suppression and CAD on chest X-rays will reduce the chances of a cancer being missed, thus improving the likelihood of diagnosing unsuspected early-stage disease.”

Related Links:

Radbound University Nijmegen Medical Center
Riverain Technologies
University of Chicago Medical Center



Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Desk Aneroid Sphyg
Diagnostix 750D+
POC Respiratory/Sore Throat Test
BIOFIRE SPOTFIRE (R/ST) Panel
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image

Explainable AI Tool Improves Brain Disorder Screening from 4D fMRI

Functional magnetic resonance imaging (fMRI) captures changes in brain activity over time, but the resulting image sequences can be difficult to analyze. Screening for brain disorders requires assessing... Read more

Critical Care

view channel
Image: Liposomes have long been used for gradual drug delivery, with their composition controlling release speed, potency, duration, and potential toxicity. (Image Credit: iStock)

New Drug Delivery System Extends Release of Local Anesthetic for Weeks

Local anesthetics used for nerve blocks often provide pain relief for only a limited period, while perioperative pain can persist much longer. Extending the duration of a nerve block therefore requires... Read more

Surgical Techniques

view channel
Image: Memo 4D Curve preserves the mitral annulus’s natural three-dimensional motion while supporting remodeling and is available in sizes up to 42 mm for a broad range of mitral pathology. (Photo courtesy of Corcym)

First Human Implant Performed With New Open Mitral Annuloplasty Ring

In mitral valve repair, clinicians aim to preserve the mitral annulus’s three-dimensional motion while providing enough support for effective remodeling. Ring preferences vary between open and closed ... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.