Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




New Tool Images Uterine Contractions in Real Time to Identify High-Risk Pregnancies

By HospiMedica International staff writers
Posted on 16 Mar 2023

During the labor and delivery process, the uterus contracts to expel the fetus. More...

Irregularities in these contractions can result in premature delivery or labor arrest, creating the need for a Cesarean (C-section) delivery. Both preterm birth and C-sections can increase the likelihood of injury or death for the parent and infant, potentially leading to long-term neurodevelopmental disability for the child. Identifying the specific type of uterine contractions that cause premature birth or labor arrest can aid researchers in developing methods to slow or prevent the onset of these contractions. However, current clinical techniques to measure uterine contractions, such as tocodynamometry and an intrauterine pressure catheter, are invasive and only provide limited information related to contraction duration and intensity.

Researchers at Washington University School of Medicine (St. Louis, MO, USA) have developed new imaging technology that can create 3D maps of uterine contractions in real-time, displaying both the magnitude and distribution of the contractions across the entire surface of the uterus during labor. Drawing from imaging methods frequently employed in examining the heart, this cutting-edge technology allows for noninvasive monitoring of uterine contractions with unprecedented detail, unlike currently available tools that only indicate the presence or absence of a contraction. The new imaging tool, called electromyometrial imaging (EMMI), provides real-time 3D images and maps of contractions during labor, generating new types of metrics and images that enable the quantification of contraction patterns. This groundbreaking non-invasive imaging technique lays the foundation for improved labor management, especially for preterm birth.

The EMMI technique integrates two types of noninvasive scans - a fast anatomical MRI used to capture a high-quality image of the uterus during the early term pregnancy stage (37 weeks gestation), and a multi-channel surface scanning electromyogram that utilizes sensors positioned along the abdominal region to monitor contractions during delivery. These data are then combined and processed into comprehensive three-dimensional uterine maps, which utilize warm colors to denote areas of the uterus that are activated earlier in a contraction, cool colors to display areas that are activated later, and gray areas to indicate inactive or non-contracting regions. Over time, a sequence of maps is created, producing a visual time lapse that shows where contractions originate, how they expand and/or synchronize, and any patterns that arise in a typical pregnancy versus one that may be experiencing difficulties or abnormalities.

In the new study, the team tailored EMMI for human clinical use and tested it among a group of 10 women with healthy pregnancies. The study revealed that uterine contractions exhibit less predictability and consistency than heart contractions measured using similar technology. Subsequent labor contractions can differ in the initiating region and the direction of progression even with the same patient. Additionally, the team discovered that initiation sites or "pacemakers" of the uterine contractions do not occur in fixed anatomical regions, as in the heart. These findings serve to increase the value of the EMMI imaging technology, as it is capable of tracking changes through progressive contractions.

The study featured primiparous (first-time birth) patients as well as multiparous (previously given birth) patients. The researchers discovered that primiparous patients exhibited longer contractions with greater variability than multiparous patients who had more efficient and productive contractions. This could be attributed to a "memory effect" of the uterus which may recall its previous labor experiences. The next objective of the researchers is to measure normal uterine contractions to discern whether they are productive and leading toward childbirth. In resource-restricted areas, such a detailed imaging technology could improve childbirth safety. To enhance accessibility, the researchers aim to swap costly MRI scans (uncommon in many regions globally) with less expensive, portable ultrasound imaging. Additionally, the team is creating disposable electrodes and wireless transmitters to promote mass usage of the technology.

“There are all kinds of obstetrics and gynecological conditions that are associated with uterine contractions, but we don’t have very accurate ways of measuring them,” said senior author Yong Wang, Ph.D., an associate professor of obstetrics & gynecology, of electrical & systems engineering, of radiology, and of biomedical engineering. “With this new imaging technology, we are basically upgrading the standard way of measuring labor contractions - called tocodynamometry - from one-dimensional tracing to four-dimensional mapping. This kind of information could help improve care for patients with high-risk pregnancies and identify ways to prevent preterm birth, which occurs in about 10% of pregnancies globally.”

Related Links:
Washington University School of Medicine 


Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Glucose Meter
StatStrip®
Resorbable Bovine Collagen Membrane
GenDerm
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: Adobe Stock

Noninvasive Imaging Approach Aims to Detect Basal Cell Carcinoma Before It Becomes Visible

Basal cell carcinoma is the most common form of skin cancer and can damage nearby structures such as the nose or eyes when it develops on the face. Diagnosis typically depends on visible skin changes,... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.