AI-Supported Mammography Screening Detects 20% More Cancers and Halves Radiologist Workload

By HospiMedica International staff writers
Posted on 03 Aug 2023

Mammography screening for breast cancer has been proven to enhance prognosis and lower mortality by early detection of the disease, enabling timely treatment. More...

However, it is estimated that 20-30% of interval cancers, which should have been detected in the prior screening, are overlooked, and numerous suspicious findings often prove benign. To ensure high sensitivity, European guidelines advise having two radiologists review the mammograms, but there's a shortage of breast radiologists in many countries and it takes over a decade to train a radiologist in becoming proficient in reading mammograms.

Artificial intelligence (AI) has been suggested as a potential automated second reader for mammograms, which could lessen the radiologist’s workload and enhance screening accuracy. The technology has shown promising results in retrospective studies using AI to triage examinations to single or double reading and aiding radiologists in identifying suspicious features to reduce false negative results with the use of computer-aided detection (CAD). However, there has been very less solid evidence from prospective randomized trials to support this. Now, an interim safety analysis of the first randomized controlled trial of its kind, involving over 80,000 Swedish women, has discovered that AI-assisted mammography analysis matches the efficacy of two breast radiologists in detecting breast cancer, without an increase in false positives and reducing the screen-reading workload by nearly half.

In a study conducted by researchers at Lund University (Lund, Sweden;), 80,033 women aged 40-80 years who underwent mammogram screening at four locations in southwest Sweden from April 2021 to July 2022 were randomly assigned to either AI-supported analysis (where a commercial AI-supported mammogram reading system examined the mammograms before one or two radiologists also read them) or standard analysis carried out by two radiologists without AI support. This initial assessment of the Mammography Screening with Artificial Intelligence (MASAI) trial compared early screening performance and screen-reading workload between the two groups.

The minimum clinically acceptable limit for safety in the AI-supported group was set at a cancer detection rate exceeding three cancers per 1,000 screened women. The assumption was that the detection rate might fall as the majority of screening exams would undergo single reading instead of double reading. The baseline detection rate with double reading in the current screening program is five cancers per 1,000 screened women. In the AI-supported analysis, the AI system initially analyzed the mammography image and predicted the cancer risk on a scale from one to ten, with one being the lowest risk and 10 the highest. Images with a risk score below 10 were further analyzed by one radiologist, while images with a risk score of 10 were analyzed by two radiologists.

The system also offered CAD marks to aid radiologists in interpreting mammography images accurately. Women were recalled for further testing in case of suspicious findings. Radiologists made the final decision to recall women and were instructed to recall cases within the top 1% risk, barring clear false positives. AI failed to give a risk score in 0.8% of cases (306/39,996), which were referred to standard care (double reading). The recall rates averaged 2.2% (861 women) for AI-supported screening and 2.0% (817 women) for standard double reading without AI. These were similar to the average 2.1% recall rate in the clinic six months before the trial began, indicating that there was no decline in the cancer detection rates.

Overall, 244 women (28%) recalled from AI-supported screening were diagnosed with cancer, compared to 203 women (25%) recalled from standard screening, resulting in 41 additional cancers detected using AI. The false-positive rate was 1.5% in both groups. In general, AI-supported screening resulted in a cancer detection rate of six per 1,000 screened women compared to five per 1,000 for standard double reading without AI, equivalent to detecting one additional cancer for every 1,000 women screened. Significantly, there were 36,886 fewer screen readings by radiologists in the AI-supported group than in the control group (46,345 vs. 83,231), resulting in a 44% reduction in the radiologists' screen-reading workload.

Although the actual time saved by using AI was not measured in the trial, the researchers estimate that if a radiologist reads an average of 50 mammograms an hour, it would have taken one radiologist 4.6 months less to read the roughly 40,000 screening examinations using AI compared with the roughly 40,000 in the control arm that were double read. The MASAI trial will continue to ascertain whether AI-supported mammography screening reduces interval cancers. The final trial results determining whether the use of AI in interpreting mammography images leads to a reduction in interval cancers in 100,000 women followed over two years, and ultimately whether the use of AI in mammography screening is justified, are not expected for several years.

“The greatest potential of AI right now is that it could allow radiologists to be less burdened by the excessive amount of reading,” said lead author Dr. Kristina Lång from Lund University. “While our AI-supported screening system requires at least one radiologist in charge of detection, it could potentially do away with the need for double reading of the majority of mammograms easing the pressure on workloads and enabling radiologists to focus on more advanced diagnostics while shortening waiting times for patients.”

Related Links:
Lund University


Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Medical-Grade Display
HL2316SHTB
Resorbable Bovine Collagen Membrane
GenDerm
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Surgical Techniques

view channel
Image: Researchers developed a handheld photothermal mid-infrared spectroscopic imaging (MIRSI) system that measures just 8 square inches. Probe light from a visible (red) diode laser and pump light from a modulated quantum cascade laser (QCL) are coupled into optical fibers and delivered to a flexible, handheld imager (blue dashed box). The beams are combined at a short-pass dichroic mirror and focused onto the sample using an off-axis parabolic mirror (OAP). (Image Credit:Rohith Reddy, University of Houston)

Handheld Infrared Imaging Device Supports Tumor Margin Assessment During Surgery

Accurately determining tumor margins during surgery remains challenging. Frozen-section pathology takes time and can miss residual disease, potentially leading to repeat surgery and delayed therapy.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.