We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




CT Scanner Intelligently Adapts to Clinical Needs

By HospiMedica International staff writers
Posted on 01 Feb 2010
A computed tomography (CT) system is the world's first adaptive scanner, which adjusts itself intelligently and dynamically to the patient, aiding in dose protection, as well as adapting to new dimensions and space. More...


Recognized as one of the leading pediatric healthcare centers in the United States, St. Louis Children's Hospital (MO,USA) is further enhancing its nationally renowned pediatric care program with the installation of a Somatom Definition AS computed tomography (CT) scanner from Siemens Healthcare (Erlangen, Germany).

Although CT is a vital medical imaging tool in diagnosing illness and disease in children, there is always a concern over the amount of radiation dose a pediatric patient receives. Medical institutions, such as St. Louis Children's Hospital, strive to provide the best medical imaging exams as possible, while ensuring one of the best methods for its patients. The addition of the scanner provides the link between dose protection and imaging excellence for the Hospital's young patients.

"In light of recent studies on radiation dose and best practices for dose reduction, it is essential to employ a CT scanner that can not only ensure some dose reduction, but provide one of the fastest scan speeds, while still maintaining optimal imaging performance,” said Dr. Marilyn J. Siegel, of the division of diagnostic radiology and professor of radiology and pediatrics, St. Louis Children's Hospital. "This latest addition to our CT family allows Children's Hospital to better serve our young patients with safe, effective, quality care.”

In the July 2009 issue of the journal Radiology, a team of researchers evaluated the potential effectiveness of adaptive collimation in reducing CT radiation dose owing to z-overscanning (one of the factors responsible for radiation burden in spiral CT examinations) by using dose measurements and dose simulations. The data revealed that by using adaptive section collimation, a considerable dose reduction of up to 10% was achieved for cardiac and chest CT when measurements were performed free in air and of 7%, on average, when measurements were performed in phantoms. For scan ranges smaller than 12 cm, ionization chamber measurements and simulations indicated a dose reduction of up to 38%, according to the team's findings.

The researchers concluded that adaptive section collimation allows considerable reduction of unnecessary exposure owing to z-overscanning in spiral CT. It can be combined in synergy with other means of dose reduction, such as spectral optimization and automatic exposure control. "Siemens' unique Adaptive Dose Shield helps to address the dose issue by dynamically assisting in blocking the unnecessary dose before and after the spiral scan, ensuring that the only dose applied to the patient is dose that is clinically relevant,” said Kulin Hemani, vice president, computed tomography, Siemens Healthcare. "The desire for as little radiation exposure as possible lies at the heart of Siemens CARE philosophy, providing a wide range of dose-reduction solutions.”

CARE Dose 4D, Siemens' real-time dose modulation, assists in guaranteeing an unparalleled combination of maximum image quality at minimum dose for every patient in every spiral scan. The entire Somatom Definition AS family of scanners comes with adaptive dose shield and set of pediatric protocols to provide optimal patient care.

The scanner is able to adapt to the space constraints many facilities face today. Featuring a large bore and high-capacity patient table, the scanner requires very little floor space, with an 18-m2 footprint. This allows the scanner to fit into rooms that have traditionally been too small for high-end CT scanners.

The technology combines components in a dynamic manner, such as a large-volume coverage area with a 200-cm scan range and up to 330 msec rotation. These features allow even the most clinically challenging patients (i.e., trauma patients) to be imaged rapidly, from head to toe, with minimum difficulty.

Related Links:
Siemens Healthcare



Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Fetal Monitor
BT-380
New
Breast Imaging Monitor
Barco Coronis Onelook MDMC-32133 32MP
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: How the machine learning helps to predict charge mobility under stretched states (Photo courtesy of Chen, X., et al.)

AI Approach Helps Identify Materials for More Reliable Wearable Electronics

Wearable health monitors and electronic skin must maintain stable performance while being stretched and bent. Molecular single crystals are promising for such stretchable electronics, yet the microscale... Read more

Surgical Techniques

view channel
Image: DermiSphere application and tie-over bolster placement following Mohs excision. A, Postoperative appearance of the defects following Mohs excision. B, Application of DermiSphere to the wounds with sutures placed for tie-over bolster dressing fixation. C, Tie-over bolster dressing in place following DermiSphere application. (Mejia, N., Knauer, G., Parikh, S., Chang, A. H., Cataneo, J., Tripodi, G., Patel, S. A., & Walchak, A. Plastic and Reconstructive Surgery - Global Open (2026), https://doi.org/10.1097/GOX.0000000000008092)

Hydrogel Dermal Supports Healing of Complex Wounds After Cancer Surgery

Full-thickness skin defects following cancer excision challenge reconstructive teams because grafts and flaps can add donor-site morbidity and prolong recovery. These wounds are common on cosmetically... Read more

Business

view channel
Image: The da Vinci SP system enables single-incision or natural-orifice procedures, enhancing visualization and precision in narrow or deep anatomical spaces (Photo courtesy of Intuitive)

Robotic Single-Port System Gains CE Mark for Transvaginal Gynecologic Procedures

Intuitive (Sunnyvale, CA, USA) announced that it has received CE mark approval for use of the da Vinci SP Single Port surgical system in transvaginal gynecologic procedures, marking the first such indication... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.