We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




320-Detector CT Imaging as Effective as Invasive Tests to Evaluate Heart Blockages

By HospiMedica International staff writers
Posted on 03 Dec 2013
An ultrafast, 320-detector computed tomography (CT) scanner that shows both anatomy within coronary arteries and blood flow can effectively decide which patients require or do not require an invasive procedure to identify coronary blockages, according to an international study. More...
The researchers reported that their findings could have the potential to save millions of people worldwide from having an unnecessary cardiac catheterization.

The study, known as CORE 320, involved 381 patients at 16 hospitals in eight countries. An article on the findings was published online November 19, 2013, in the European Heart Journal. In the study, participants were evaluated with a 320-detector CT and typically used tests that are now widely used. The researchers reported that 91% of those in whom the CT scan ruled out blockages would not have needed invasive treatment such as bypass surgery or stenting. Therefore, those patients, none of whom had a history of coronary artery disease, could have avoided invasive tests because for them the CT scan was just as effective in ascertaining who would be a good candidate for revascularization as the traditional testing.

“Ours is the first prospective, multicenter study to examine the diagnostic accuracy of CT for assessing blockages in blood vessels and determining which of those blockages may be preventing the heart from getting adequate blood flow,” said Joao A. C. Lima, MD, senior author of the study and a professor of medicine and radiology at the Johns Hopkins University School of Medicine (Baltimore, MD, USA). “We found an excellent correlation in results when we compared the 320-detector CT testing with the traditional means of assessment using a stress test with imaging and cardiac catheterization.”

According to Dr. Lima, the study findings, would apply to individuals suffering from chest pain but not a heart attack based on electrocardiogram (ECG) and other indications. Many people in that setting are sent to a cardiac catheterization laboratory for additional assessment with angiography, an invasive test to look for blockages in the coronary arteries using dye and special X-rays. Approximately 30% of patients who have such catheterization are found to have minimal disease or no blockage requiring an intervention to open the vessel with a stent or bypass the vessel through surgery, reported Dr. Lima.

The 381 patients who completed the study had traditional single-photon emission computed tomography (SPECT) imaging and invasive angiography. Dr. Lima reported that SPECT, a stress-type of test, shows reduced blood flow to the heart without indicating the number or specific location of blockages.

Study participants also had two types of tests with a noninvasive 320-detector CT scanner. In the first CT test, the scanner was used to see the anatomy of vessels to assess whether and where there were blockages. That test is known as CT angiography (CTA). Then, in a second CT test with the same machine, patients were given a medication that dilates blood vessels and increases blood flow to the heart in ways similar to what happens during a stress test. The second test is called CT perfusion (CTP).

“We found that the 320-detector CT scanner allowed us to see the anatomy of the blockages and determine whether the blockages were causing a lack of perfusion to the heart,” stated lead author Carlos E. Rochitte, M.D., a cardiologist at the InCor Heart Institute, University of Sao Paulo Medical School (Brazil), “We were therefore able to correctly identify the patients who needed revascularization within 30 days of their evaluation.”

“Many patients are sent for an angioplasty when they may not need it. Our ultimate goal is to have more certainty about which patients having chest pain—without evidence of a heart attack—need an invasive procedure to open an arterial blockage,” said cardiologist Dr. Richard George, MD, an associate professor of medicine at the Johns Hopkins University School of Medicine, and a coauthor of the study. “The CTP test added significant information about the patients’ conditions and boosted our ability to identify those whose blockages were severe enough to reduce blood flow to the heart,” added Dr. George, who developed the CTP method with Lima.

The 320-detector CT provides a wide-ranging picture of the heart by making just one revolution around the body. The researchers noted that the two tests combined, CTA and CTP, still generate less radiation than a scan with the 64-detector CT scanner in widespread use today. “In our study, the amount of radiation exposure to patients from the two 320-detector CT tests was half the amount they received as a result of the traditional evaluation methods--the angiogram and nuclear medicine stress test combined,” said Dr. Lima.

The researchers noted that they would continue to monitor the patients in the study for five years, searching for any heart-related events such as heart attacks, as well as hospital admissions, or procedures.

The study was sponsored by Toshiba Medical Systems Corp. (Tokyo, Japan).

Related Links:

Johns Hopkins University School of Medicine
InCor Heart Institute, University of São Paulo Medical School



Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Patient Preoperative Skin Preparation
BD ChloraPrep
POC Respiratory/Sore Throat Test
BIOFIRE SPOTFIRE (R/ST) Panel
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: Adobe Stock

Emergency Department Campaign Reduces CT Use Without Identified Missed Injuries

Unnecessary head and cervical spine computed tomography (CT) in low-risk trauma patients exposes them to avoidable radiation, prolongs emergency department stays, and increases healthcare costs.... Read more

Surgical Techniques

view channel
Image: Researchers developed a handheld photothermal mid-infrared spectroscopic imaging (MIRSI) system that measures just 8 square inches. Probe light from a visible (red) diode laser and pump light from a modulated quantum cascade laser (QCL) are coupled into optical fibers and delivered to a flexible, handheld imager (blue dashed box). The beams are combined at a short-pass dichroic mirror and focused onto the sample using an off-axis parabolic mirror (OAP). (Image Credit:Rohith Reddy, University of Houston)

Handheld Infrared Imaging Device Supports Tumor Margin Assessment During Surgery

Accurately determining tumor margins during surgery remains challenging. Frozen-section pathology takes time and can miss residual disease, potentially leading to repeat surgery and delayed therapy.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.