Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Compact Synchrotron Simplifies Coronary Angiography

By HospiMedica International staff writers
Posted on 08 Mar 2017
An innovative miniature particle accelerator could significantly reduce the amount of contrast agents needed for coronary angiography by generating monoenergetic X-rays.

Developed by researchers at Munich Technical University and Klinikum rechts der Isar, the Munich Compact Light Source (MuCLS) mini-synchrotron can generate X-rays that have an exact monoenergetic optimal energy level. More...
While this was previously possible only with circular particle accelerators with a diameter of several hundred meters, the MuCLS is a lot smaller, about the size of a car.

Contrast agents such as iodine and gadolinium have an energy absorption edge, which means that when the substance is exposed to X-rays of certain energy level, image contrast in the marked organ is very good. But when energy levels are below the absorption edge (30 keV for iodine), contrast deteriorates rapidly. The contrast also becomes weaker at energies far above the absorption edge. Consequently, conventional broad-spectrum X-ray sources require an adequate quantity of contrast agent in order to offset this effect and obtain a sufficiently sharp image for diagnosis.

According to the researchers, using monoenergetic X-rays would make it possible to decrease the required concentration of contrast agents significantly. Iodine levels could be reduced by about one third with no loss of contrast, while for gadolinium the reduction could even greater, around 50%. The researchers added that the experimental approach can be extended in the future to dual-energy K-edge subtraction angiography, where the beam energy is oscillated rapidly between above and below the energy absorption edge. The study was published on February 9, 2017, in Nature Scientific Reports.

“Conventional X-ray sources generate a relatively broad range of energy levels. By contrast, the energy of X-rays produced by the MuCLS can be controlled much more precisely,” said lead author physicist Elena Eggl, PhD, of TUM. “The MuCLS is the very first machine of its kind; moreover, it is designed for fundamental research, and not for examining patients. But with detailed computer simulations and tests with a pig's heart, using blood vessels dyed with iodine, [we] were able to demonstrate feasibility of the method.”

“Soft tissues such as organs and blood vessels are nearly impossible to examine in X-ray images; to detect a narrowing or other changes in coronary blood vessels, patients are therefore usually injected with an iodinated contrast agent,” said senior author Daniela Münzel, MD, an adjunct teaching professor for radiology at Klinikum rechts der Isar. “These substances can sometimes be hazardous to health, particularly in patients with kidney insufficiency; complications may arise, in some cases even kidney failure.”


Gold Member
12-Channel ECG
CM1200B
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Digital Radiography System (Ceiling Free)
Digix CF Series
Radiofrequency Generator
GX1
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.