Axillary Radiotherapy and SNL Surgery Show Comparable Outcomes

By HospiMedica International staff writers
Posted on 31 Dec 2018
Patients with early-stage breast cancer had similar recurrence and survival rates for both axillary lymph node radiotherapy (RT) and dissection, according to a new study.

Researchers at the Netherlands Cancer Institute (NKI; Amsterdam), the European Organisation for Research and Treatment of Cancer (EORTC; Brussels, Belgium), and other institutions conducted a study in 4,806 patients with early-stage, clinically node-negative breast cancer, of whom 1,425 went on to have a positive sentinel lymph node (SLN) biopsy. More...
Of these, 744 were randomly assigned to the axillary lymph node dissection group, and 681 to the axillary RT group. After 10 years, 1.82% of those assigned to axillary RT had axillary recurrence, compared with 0.93% of those assigned to dissection.

In addition, distant metastasis-free survival was 78.2% among those assigned to axillary RT and 81.7% among those assigned to axillary lymph node dissection; overall survival in the two arms was 81.4% percent and 84.6%, respectively. A significantly greater proportion of patients assigned to axillary RT went on to develop a second primary cancer (11%) than did patients assigned to axillary lymph node dissection (7.7%). The difference was mainly due to a higher incidence of contralateral breast cancer in the patients treated with axillary RT. The study was presented at the annual San Antonio Breast Cancer Symposium, held during December 2018 in San Antonio (TX, USA).

“Our new 10-year data show that axillary radiotherapy and axillary lymph node dissection provide excellent and comparable overall survival, distant-metastasis-free survival, and locoregional control,” said lead author and study presenter radiation oncologist Mila Donker, MD, PhD, of NKI. “We believe that axillary radiotherapy should be considered a good option for patients who have a positive sentinel lymph node biopsy, instead of complete surgical clearance of the axillary lymph nodes.”

“Traditionally, those patients who had cancer detected in a SLN biopsy underwent axillary lymph node dissection, which is an effective but invasive surgical procedure that is associated with adverse side effects such as lymphedema and difficulties moving the arm,” said senior author surgical oncologist Emiel Rutgers, MD, PhD. “There may be some patients who do not need axillary treatment, even if they have a positive SLN biopsy. Moving forward, we need to better tailor treatment for each individual patient. Some will still need axillary treatment, and our data indicate that axillary radiotherapy is a good option here.”

Finding metastatic cancer cells during breast cancer surgery requires first identifying the position of the SNLs, which have a diameter of just a few millimeters, and then excising them for hisotpathology. If the cancer has not yet metastasized to an SLN, axillary lymph node excision can be omitted, thus preventing subsequent lymphedema and maintaining the patient's quality of life after surgery.

Related Links:
Netherlands Cancer Institute
European Organisation for Research and Treatment of Cancer


Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Vessel Sealing Instrument
ERGOseal
Surgical System
Stealth AXiS
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie MellonImage: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie Mellon University)University)

Portable Artificial Lung Technology Could Reshape Care for Chronic Lung Disease

Chronic lung disease can leave patients dependent on prolonged mechanical ventilation or awaiting transplantation, both of which carry substantial morbidity and healthcare costs. Ventilatory support may... Read more

Surgical Techniques

view channel
Image: The thin foetoscope is guided through the abdominal wall to the placenta. Small magnets in its tip react to an externally generated magnetic field, enabling the instrument to be bent with precision. The robotic platform is designed to occlude shared blood vessels in the placenta of twins with twin-to-twin transfusion syndrome. (Image Credit: created with BioRender.com, ETH Zurich)

Robotic Platform Advances Fetoscopic Treatment of Twin-to-Twin Transfusion Syndrome

Twin-to-twin transfusion syndrome is a life-threatening complication in monochorionic twin pregnancies caused by unbalanced placental blood flow. Definitive treatment requires endoscopic laser coagulation... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.