Novel Ingestible Capsule X-Ray Dosimeter Enables Real-Time Radiotherapy Monitoring

By HospiMedica International staff writers
Posted on 17 Apr 2023

Gastric cancer ranks among the most prevalent cancers worldwide. More...

Precision is vital in modern radiotherapy, as it aims to target tumor cells while minimizing damage to healthy tissue. However, challenges such as diverse patient populations, treatment uncertainties, and varying delivery methods result in low efficacy and inconsistent outcomes. Real-time monitoring of radiation doses, particularly within the gastrointestinal tract, could enhance radiotherapy precision and effectiveness, but it remains a difficult task. Furthermore, current methods for tracking biochemical indicators like pH and temperature fall short in providing a comprehensive evaluation of radiotherapy. Now, a new invention may improve gastric cancer treatment by boosting the precision of radiotherapy, which is often combined with surgery, chemotherapy, or immunotherapy.

Conventional clinical dosimeters, such as metal-oxide-semiconductor field-effect transistors, thermoluminescence sensors, and optically stimulated films, are typically placed on or near a patient's skin to estimate the radiation dose absorbed in the targeted area. While electronic portal imaging devices have been investigated for treatment verification, these devices can be costly and absorb radiation, thereby reducing the patient's intended radiation dose. Ingestible sensors have been limited to monitoring pH and pressure, creating the need for an affordable swallowable sensor that can simultaneously track biochemical indicators and X-ray dose absorption during gastrointestinal radiotherapy. A research team at the National University of Singapore (NUS, Singapore) has created an ingestible X-ray dosimeter capable of real-time radiation dose detection. By integrating their innovative capsule design with a neural-network-based regression model that calculates radiation dose based on data captured by the capsule, the researchers achieved approximately five times more accurate dose monitoring compared to existing standard methods.

The novel ingestible X-ray dosimeter can measure radiation dose, pH changes, and temperature in real time during gastrointestinal radiotherapy. The capsule's main components consist of a flexible optical fiber wrapped in nanoscintillators that emit light in response to radiation, a pH-sensitive film, a fluidic module with multiple inlets for dynamic gastric fluid sampling, dual sensors for dose and pH measurement, a microcontroller circuit board that processes photoelectric signals for transmission to a mobile app, and a compact silver oxide battery to power the capsule.

Upon ingestion and reaching the gastrointestinal tract, the nanoscintillators emit a stronger luminescence when exposed to increased X-ray radiation. A sensor within the capsule measures this glow to determine the radiation dose delivered to the targeted area. Simultaneously, the fluidic module collects gastric fluid for pH detection by the color-changing film. This color shift is recorded by a second sensor inside the capsule. Additionally, both sensors can detect temperature, providing insight into potential adverse reactions to radiotherapy treatment, such as allergic responses.

The microcontroller circuit board processes photoelectric signals from the two sensors and transmits the information to a mobile app using Bluetooth technology and an antenna. The mobile app employs a neural network-based regression model to process the raw data, displaying information such as radiotherapy dose, temperature, and pH of the tissues undergoing treatment. The capsule dosimeter measures 18mm in length and 7mm in width, a standard size for supplements and medications, and has a production cost of S$50.

While currently designed for monitoring radiotherapy doses in gastric cancer, the capsule could also be adapted to track treatment for various malignancies with modifications to its size. For instance, a smaller capsule could be inserted into the rectum for prostate cancer brachytherapy or the upper nasal cavity for real-time measurement of absorbed doses in nasopharyngeal or brain tumors, minimizing radiation damage to adjacent structures. The research team is striving to advance their innovation toward clinical application. Future research includes determining the capsule's location and orientation after ingestion, devising a reliable positioning system to secure the capsule at the target site, and refining the accuracy of the ingestible dosimeters for safe and effective clinical use.

“Our novel capsule is a game-changer in providing affordable and effective monitoring of the effectiveness of radiotherapy treatment. It has the potential to provide quality assurance that the right dose of radiation will reach patients,” said Professor Liu Xiaogang from the Department of Chemistry under the NUS Faculty of Science, who led the research team.

Related Links:
NUS 


Gold Member
Blood Gas Analyzer
i-Check200
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Radiofrequency Generator
GX1
Digital Radiography System (Ceiling Free)
Digix CF Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: Adobe Stock

Noninvasive Imaging Approach Aims to Detect Basal Cell Carcinoma Before It Becomes Visible

Basal cell carcinoma is the most common form of skin cancer and can damage nearby structures such as the nose or eyes when it develops on the face. Diagnosis typically depends on visible skin changes,... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.