We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Events

26 Oct 2026 - 29 Oct 2026
16 Nov 2026 - 19 Nov 2026

Wearable Patch Enables Continuous Noninvasive Cholesterol and Triglyceride Monitoring

By HospiMedica International staff writers
Posted on 14 Aug 2026

Cholesterol and triglyceride testing typically relies on phlebotomy and intermittent lipid panels, limiting real-time assessment of cardiovascular and metabolic risk. More...

Noninvasive monitoring could reduce these barriers while providing continuous measurements that complement laboratory testing. However, accurately linking sweat biochemistry to blood lipid levels has been challenging because sweat composition varies with physiology and perspiration. A new study shows that a wearable patch can continuously assess lipid status by analyzing sweat.

Researchers at the California Institute of Technology (Caltech) have developed a stick-on sweat patch that continuously profiles lipids, including cholesterol and triglycerides. The device analyzes sweat to estimate corresponding blood lipid levels, allowing repeated measurements without blood draws. The approach is presented as a wearable system designed for continuous lipid profiling.

The sensor’s biochemical architecture uses a two-step enzymatic cascade to quantify sweat cholesterol. Because much of sweat cholesterol is present in esterified form and cannot be detected directly, the first reaction converts esterified cholesterol to free cholesterol. A subsequent oxidation step generates hydrogen peroxide, which the electrochemical sensor measures. For triglyceride detection, the patch integrates a polymer that traps and gradually releases adenosine triphosphate (ATP) into sweat, maintaining the cofactor supply for more than 20 hours.

To bridge the non-linear relationship between sweat and blood lipids, the team applies a causal machine learning model to the sensor readouts. The model incorporates physiological factors—including body mass index (BMI), sex, and sweat rate—to refine estimates of blood lipid concentrations. This integration is designed to deliver continuous lipid assessments from noninvasive sweat sampling.

Preclinical testing on 24 participants and the device description are presented in Nature Sensors on July 29, 2026. The researchers indicate the wearable could help provide earlier warning related to cardiovascular or metabolic diseases. The work highlights a pathway for translating sweat chemistry into clinically relevant lipid information using on-body sensing and computational modeling.

"How many people actually get their blood drawn regularly? I haven't done this myself for at least two years, probably, That's why we think a noninvasive way of monitoring lipids will be critical," said Wei Gao, professor in the Cherng Department of Medical Engineering at the California Institute of Technology and Heritage Medical Research Institute Investigator.

Related Links
Caltech


Gold Member
12-Channel ECG
CM1200B
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Surgical System
Stealth AXiS
Monitor/Defibrillator
Zenix
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image:The NCIBT team with the cath lab members celebrating the completion of the study. (Image Credit: UC Davis)

Dual-Imaging Catheter Completes Initial Human Evaluation of Coronary Plaque

Atherosclerosis involves plaque buildup in arterial walls that can narrow blood vessels and increase the risk of heart attack, stroke, and other serious cardiovascular conditions. In coronary arteries,... Read more

Patient Care

view channel
Image: Researchers evaluated the Omni 128 cm long-axial field-of-view PET/CT system, which captures more of the body and radiotracer signal at once, potentially enabling shorter scans. (Photo courtesy of GE HealthCare)

Total-Body PET/CT Scanner Enables One-Minute Diagnostic-Quality Cancer Imaging

Positron emission tomography/computed tomography (PET/CT) combines radiotracer-based functional imaging with anatomical detail to diagnose, stage, and monitor cancer. Conventional scanners image the body... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: Steris is expanding its healthcare consumables portfolio through an agreement to acquire Xodus Medical, a surgical products business focused on patient and operating room staff safety.

Steris to Expand Surgical Safety Portfolio With $2.1 Billion Xodus Medical Deal

Steris has signed a definitive agreement to acquire Xodus Medical, a specialty surgical products business based in Pennsylvania, for $2.1 billion at closing. The acquisition will expand Steris’s healthcare... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.