Gravity-Powered Biomedical Device Paves Way for Low Cost POC Diagnostic Testing

By HospiMedica International staff writers
Posted on 14 Jul 2023

The need for simple, user-friendly, point-of-care devices continues to exist. More...

Many prototype and market-ready devices aim to simplify diagnosis and crucial biomarker measurement processes using minimal liquid samples, power, and professional knowledge. These innovations aim to enhance healthcare delivery for the vast population residing in low-resource locales, far from well-equipped hospitals and qualified medical personnel. These tests generally share certain prerequisites: they need to transport, combine, and assess minute biological sample-containing droplets and their active ingredients, enabling specific biomarker measurements. High-end devices employ miniature electric pumps to facilitate these reactions, while others leverage the dynamics of liquids within microchannels, or microfluidics, to produce a suction-like effect. Each method comes with its own distinct benefits and challenges. Now, researchers have demonstrated a first-of-its-kind approach that only uses gravity to power point-of-care biomedical devices and also offers certain advantages over currently existing platforms.

Biomedical engineers at Duke University (Durham, NC, USA) have devised a completely new approach for building point-of-care diagnostic tools, which only leverages gravity to transport, mix, and manipulate the liquid droplets involved. This proof-of-concept uses readily available materials and minimal power to interpret results, making it a potentially beneficial option for use in settings with limited resources. The innovative gravity-based technique is based on a selection of nine commercially available surface coatings that can fine-tune the wettability and slipperiness at any given point in the device, thereby controlling how much droplets spread into pancakes or remain spherical, while also influencing their ease of movement down an incline.

By using these surface coatings in smart combinations, all necessary microfluidic elements required for a point-of-care test can be generated. For instance, if a certain location is extremely slippery and a droplet is positioned at a juncture where one side pulls liquid flat and the other pushes it into a ball, it acts like a pump and accelerates the droplet toward the former. The scientists devised numerous elements to manage the motion, interaction, timing, and sequence of multiple droplets within the device. Merging these elements, they fabricated a prototype test to measure human serum lactate dehydrogenase (LDH) levels. They carved channels into the testing platform to create designated routes for droplet passage, each coated with a substance preventing droplets from sticking along the way. Specific points were also pre-treated with dried reagents needed for the test, which are absorbed by droplets of simple buffer solution as they traverse the channels.

The maze-like test is then sealed with a lid equipped with holes for the sample and buffer solution to be dripped in. Once filled, the test is inserted into a box-shaped device with a handle that rotates the test by 90 degrees, allowing gravity to take over. The device also features a simple LED and light detector for swift and easy color-based test result assessment. This enables the scientists to label three different biomarkers with distinct colors for varying tests. In the LDH prototype test, the biomarker is marked with a blue molecule. A basic microcontroller measures the depth of the blue tint and the rate of color change, signifying the quantity and concentration of LDH in the sample, to yield results. This novel demonstration presents a new approach to the development of affordable, low-energy, point-of-care diagnostic devices. While the team intends to further refine their concept, they also hope it will spark interest and lead to the creation of similar tests by other researchers.

“Most microfluidic devices need more than just capillary forces to operate,” said Ashutosh Chilkoti, the Alan L. Kaganov Distinguished Professor of Biomedical Engineering at Duke. “This approach is much simpler and also allows very complex fluid paths to be designed and operated, which is not easy or cheap to do with microfluidics.”

Related Links:
Duke University 


Gold Member
12-Channel ECG
CM1200B
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Rapid Sepsis Test
SeptiCyte RAPID
Desk Aneroid Sphyg
Diagnostix 750D+
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: Masimo smartSET pulse oximetry with PPG AFib and OIRD Detection (Photo courtesy of Masimo)

Smart Pulse Oximetry Supports Earlier Recognition of Arrhythmias and Respiratory Risk

On general care floors, respiratory compromise and arrhythmias can develop between routine checks. Atrial fibrillation often goes undiagnosed in older adults, while opioid-induced respiratory depression... Read more

Surgical Techniques

view channel
Image: A UTSW clinical trial studied a treatment strategy for kidney cancer with inferior vena cava tumor thrombus (IVC-TT) that used targeted radiation on the tumor thrombus followed by surgery to remove the kidney. (Photo courtesy of UT Southwestern)

Targeted Radiotherapy Before Surgery Improves Control of Kidney Cancer Thrombus

Inferior vena cava tumor thrombus occurs when kidney cancer extends into the body’s largest vein, potentially obstructing blood flow, progressing toward the heart, and making surgery more complex.... Read more

Patient Care

view channel
Image Credit: Adobe Stock

AI Platform Personalizes Support Between Visits for Cancer Survivors

Cancer survivors often manage persistent side effects after treatment, including fatigue, anxiety, uncertainty, symptoms, stress, and questions between appointments. Clinical teams need ways to maintain... Read more

Medical Imaging

view channel
Image: Brain PET imaging could help identify Alzheimer’s patients most likely to benefit from available therapies (Image Credit: iStock)

Amyloid and Tau PET Guide Selection and Monitoring of Alzheimer’s Therapy

Alzheimer’s disease is the most common form of dementia and can be difficult to distinguish from other causes of cognitive decline. According to the World Health Organization (WHO), 57 million people were... Read more

Business

view channel
Image: Steris is expanding its healthcare consumables portfolio through an agreement to acquire Xodus Medical, a surgical products business focused on patient and operating room staff safety.

Steris to Expand Surgical Safety Portfolio With $2.1 Billion Xodus Medical Deal

Steris has signed a definitive agreement to acquire Xodus Medical, a specialty surgical products business based in Pennsylvania, for $2.1 billion at closing. The acquisition will expand Steris’s healthcare... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.