CT Provides Effective Diagnosis of Patients with Large Bowel Obstruction

By MedImaging staff writers
Posted on 06 May 2008
The use of computed tomography (CT) has been found to be very effective in validating large bowel obstruction and identifying the site and cause of the obstruction, according to a recent study.

"There is very little published evidence regarding the diagnostic efficiency of CT in large bowel obstruction [LBO],” said Sathi Sukumar, M.D., lead author of the study, conducted by researchers at the University of South Manchester (Manchester, UK). More...
"Large bowel obstruction is a common clinical problem and plain films have been shown to be unreliable. Contrast enemas, the conventional way of investigating LBO is invasive, gives only limited information and is sometimes technically not possible and difficult to interpret,” said Dr. Sukumar.

The study consisted of 42 patients who were identified for follow-up after LBO; large bowel dilatation or pseudo-obstruction was noted. On CT, 31 patients were diagnosed with large bowel obstruction, eight with pseudo-obstruction, and three were indeterminate. Of the 31 cases that were diagnosed with LBO, 27 were confirmed by surgery or endoscopy. Of the eight patients with pseudo-obstruction, no surgical/endoscopic intervention was required and follow-up confirmed pseudo-obstruction. The study demonstrated that of the three patients with indeterminate CT, two were later confirmed as carcinomas and the other had a negative laparotomy.

According to the study, causes of large bowel obstruction varied from common conditions such as carcinoma, volvulus, and diverticular stricture to rare causes such as hernias, inflammatory stricture, and gallstone obstruction at unusual sites. The sensitivity and specificity of CT in diagnosing LBO was 94% and 100%, respectively.

"The results of this study could simplify the diagnostic process dramatically. A large number of patients in our study were frail or unwell, so it is particularly important in this group that diagnosis is achieved with the least invasive and quickest method possible,” said Dr. Sukumar. "Previously and even now, at some centers contrast enema is used and this can be technically difficult and highly unpleasant in this group of patients. CT in this situation is performed with no bowel preparation and can be done quickly and easily so. For the referring physician, CT not only confirms or excludes the diagnosis of large bowel obstruction, it also gives additional information, which is important for management, such as impending perforation or perforation. Early intervention in these patients will reduce morbidity and even save lives.”

The full results of the study were presented on Thursday, April 17, 2008, during the American Roentgen Ray Society's annual meeting in Washington, DC, USA.


Related Links:
University of South Manchester

Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Medical Adhesive
MED 5570U
Monitor/Defibrillator
Zenix
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Clinical LLM Performance Improves by >300% When Provided with High-Quality Real-World Evidence in New Precision Medicine Benchmark (Photo courtesy of Atropos Health)

New Benchmark Highlights Evidence Gaps in AI Responses to Clinical Questions

Many clinical decisions still rely on limited evidence, while most artificial intelligence benchmarks overlook the patient context that shapes real-world care. General large language models can also struggle... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.