Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Handheld Device Improves Targeted Cell Collection for Early Ovarian Cancer Assessment

By HospiMedica International staff writers
Posted on 25 Sep 2026

High-grade serous ovarian cancer is the most common form of ovarian cancer, and many cases are thought to originate in the fallopian tubes. More...

Because precursor lesions can be microscopic, they are difficult to sample and detect at an early stage. Five-year survival can exceed 90% when ovarian cancer is diagnosed early, but falls below 50% when the disease is detected at stages 3 or 4. To improve access to these hard-to-sample tissues, researchers have developed a device that collects living cells from specific anatomical sites.

Researchers at the Massachusetts Institute of Technology (MIT; Cambridge, MA, USA), working with colleagues at Johns Hopkins University (Baltimore, MD, USA), developed a handheld fluidic-shear device for targeted cell collection. The 3D-printed microfluidic device uses one syringe to create a vacuum seal against the tissue. A second syringe drives liquid through a channel, generating shear stress that gently detaches cells from a small area while leaving surrounding tissue intact.

In a study published in Device on September 24, 2026, the researchers used the system to sample newly excised tissue and recover living cells for cultivation. They tested it on fresh human fallopian tube samples and compared its cell-collection performance with conventional approaches. Cells collected with the device remained viable and grew in culture more readily than cells detached by conventional methods. The team also used collected fallopian tube cells to grow organoids before returning the tissue samples for conventional pathology.

Tests across different cell types showed that the applied shear stress could be adjusted for collection. Loosely adherent prostate cancer cells detached at 1 pascal of stress. By contrast, only a few bone cancer cells detached at 5 pascals.

The researchers expect initial use to focus on tissue already removed from the body. They are also exploring optical approaches to identify suspicious regions that could then be sampled with the device. Future goals include collecting cells inside patients and using living patient-derived cells to study disease and test treatment responses.

“We wanted to collect living cells from specific regions of the fallopian tube while leaving the surrounding tissue intact. Once we have these living cells, there are many things we can do with them. We can use them for diagnostics, grow them into organoids and build living models of disease. Ultimately, this could allow us to test how an individual patient's cells respond to different treatments and help us develop more personalized medicines,” said Kripa Varanasi, senior author of the study and professor of mechanical engineering at MIT.

Related Links
MIT


Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Surgical System
Stealth AXiS
Pediatric Mask
Respire SOFT
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.