We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Paradigm Shift in MRI Detection Results in Wider, Clearer Images

By HospiMedica International staff writers
Posted on 31 Mar 2009
Unconventional thinking led a Swiss student to make a discovery that could revolutionize magnetic resonance imaging (MRI) technology. More...
He succeeded in exciting and imaging nuclear magnetic resonance in the human body by propagating electromagnetic waves.

It was a colleague's MR images that gave David Brunner, a Ph.D. student from the Institute of Biomedical Engineering of the ETH Zurich (Switzerland) and the University of Zurich, the plan to use propagating waves for MRI. His colleague had taken images of a hand and captured so-called fold-over artifacts that seemed to originate from outside the detector. Clearly, signals were recorded not only from the target region but also from a considerable distance--although the detector was supposed to be sensitive only to its immediate surroundings. "This is only possible if the signals travel, that is, if they propagate as waves," explained Dr. Brunner.

Dr. Klaas Prüssmann, professor at the same institute and Mr. Brunner began to look for the optimal conditions for propagating waves, together with other researchers from ETH Zurich and the University of Zurich. For efficient signal transmission they required a suitable waveguide with a sufficient diameter to support wave propagation. Here, the researchers were helped by a stroke of luck as their strongest magnet with a field strength of 7 Tesla (T), was just wide enough (58 cm) for unhindered propagation at the resonance frequency of 300 MHz. Lined with a conductive material, the magnet's bore effectively acts as a waveguide. An antenna was used to generate propagating waves that penetrated the imaging sample and passed through the entire bore virtually without loss. Resonance signals, again in the form of propagating waves, were recorded by the same antenna, yielding MR images of greater coverage than previously possible at such high fields.

Conventionally, MRI is based upon so-called near-field coupling, for which the detector is placed as close as possible to the body. Stationary radiofrequency fields are used to excite magnetic resonance in hydrogen nuclei. According to theory, a good MRI detector is a resonator with optimal near-field coupling to the sample. However, at 7 T the signal wavelength in tissue is so short, approximately 10 cm, that the stationary radiofrequency fields form node regions, from which no image information can be obtained.

As a consequence, structures that are larger than the wavelength--such as the human head --can no longer be fully covered with the traditional concept. The scientists have now solved this problem by abandoning the stationary approach and instead adopting traveling radiofrequency waves, which do not form field nodes. In their study they show that the new method permits covering large parts of the body more uniformly, while receiving the underlying signals across distances in the meter range.

Current clinical MRI systems typically operate at field strength of 1.5 T, corresponding to a signal frequency of 64 MHz. At this relatively low frequency the traditional, stationary detection principle does not limit coverage because the signal wavelength is much larger. However, compared to higher fields, the current clinical systems are less sensitive, yielding lower spatial resolution. Furthermore, close-range transmitters and detectors are often perceived as uncomfortable by patients and require special precautions to rule out exposure to excessive short-range electric fields in the event of malfunction.

Initial imaging results from a volunteer's lower leg and foot demonstrate more extensive coverage than possible with a traditional detector. "And the fact that MRI signals can be received with an antenna and across such large distances is remarkable; it's a paradigm shift," said Dr. Klaas Prüssmann. The translation into clinical settings will take time, nevertheless. "Unfortunately, the cost of the strong magnets is still substantial and the clinical benefits of very high fields first need to be proven in extensive studies," he says. However, traveling-wave MR detection from large volumes holds potential not only for medical imaging but could also facilitate very different applications. For instance, it may be used to examine large numbers of material samples or small animals in parallel for high-throughput screening.

MRI is the imaging variant of nuclear magnetic resonance (NMR). It is based on an effect that occurs when hydrogen atoms are brought into a strong, static magnetic field and additionally exposed to an oscillating magnetic field in the radiofrequency range. At a certain resonance frequency, the nuclei of the hydrogen atoms respond by oscillating and emitting weak radiofrequency signals themselves. MRI amounts to detecting these signals and rendering them in the form of images. In such depictions the contrast between different tissues reflects different hydrogen content and differences in the nuclei's microscopic surroundings.

The foundations of MRI were laid over 60 years ago by the American Edward M. Purcell and ETH Zurich graduate Felix Bloch through their discovery of NMR. In recognition of this achievement the two researchers jointly received the Nobel Prize in Physics in 1952. NMR went on to revolutionize chemistry and structural biology, including key developments for which the Zurich-based scientists Richard R. Ernst and Kurt Wüthrich received Nobel Prizes in Chemistry.

The study was published in the February 26, 2009, issue of the journal Nature.

Related Links:

ETH Zurich
University of Zurich



Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Biochip Array Technology
Evidence MultiSTAT Drugs of Abuse Urine Multiplex Panel
Medical Adhesive
MED 5570U
Medical-Grade Display
HL2316SHTB
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image Cedit: Shutterstock

New Light-Activated Platform Advances Glioblastoma Surgery and Postoperative Treatment

Glioblastoma, an aggressive primary brain tumor, infiltrates healthy tissue and resists complete surgical removal. Residual microscopic disease and the blood–brain barrier limit the effectiveness of adjuvant... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.