Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Siemens Healthineers

Provides customized electronic systems and advanced imaging, diagnostics, therapy, and healthcare IT solutions for th... read more Featured Products: More products

Download Mobile App




CT Technology Offers 50% Lower Dose for Highly Sensitive Patient Groups

By HospiMedica International staff writers
Posted on 26 Nov 2013
A new computed tomography (CT) system offers early detection exams and functional diagnoses with up to 50% lower radiation dose, which can help make treatment decisions easier. More...
The technology also minimizes artifacts in cardiac and thoracic examinations.

Siemens Healthcare (Erlangen, Germany) had its first public presentation worldwide November 2013 at the University Medical Center Mannheim (Heidelberg, Germany). In its first few weeks of clinical use at Mannheim’s Institute for Clinical Radiology and Nuclear Medicine, the third-generation of dual- source CT scanners (each with two radiation tubes and detectors) enabled considerably more rapid and more precise diagnoses at reduced doses.

In addition, the high-end CT now offers customized diagnoses for challenging patients, e.g., for very young patients or renal insufficiency patients, the very ill, and obese patients. “In a general population with a very complex age and disease structure, this new CT scanner can solve the problems presented by every radiological situation for virtually every patient,” said institute director Prof. Stefan Schönberg.

Patients suffering from renal insufficiency will benefit from the substantial reduction in contrast medium. Early detection examinations and functional four-dimensional (4D) imaging can be conducted using up to 50% lower radiation dose. This means that this procedure can now be used on a routine basis and physicians can make faster and more well founded decisions as to which tumor therapy to use for the individual in question.

“Somatom Force negates many aspects of computed tomography that up to now have limited its application. For example, the administration of contrast medium that proves problematic for many patients can be greatly lowered,” said Walter Märzendorfer, CEO of CT and radiation oncology at Siemens Healthcare.

Up to 20% of patients suffer from renal insufficiency. Contrast medium containing iodine can place extra burden on the kidneys of older patients and especially those with chronic illnesses. Initial examinations in Mannheim revealed that the average quantity of contrast medium administered in thoracic examinations could be lowered from between 90–110 mL to between 25–35 mL. This is made possible by the two Vectron X-ray tubes in Somatom Force, which enable routine examinations at very low tube voltages of 70–100 kilovolts.

As the contrast-to-noise ratio rises, the amount of contrast medium can be lowered accordingly. The CT system can also deliver considerable added benefits in treatment control. 4D imaging, which shows the function of organs and vessels next to their morphology, is particularly important here because it allows additional information to be gathered about primary tumors and metastases. A disadvantage of this dynamic perfusion was that, up to now, high dose values of more than 50 millisievert (mSv) in specific cases were required, e.g., for liver imaging. This dose can now be more than halved with the Somatom Force system. In one of the Mannheim cases, just 14.7 mSv was required.

Such values enable the procedure to be used on a regular basis, thereby enabling faster and more careful decisions to be made about which treatment is most suitable for an individual patient. In the case of novel but also very expensive antiangiogenesis therapies, which suppress blood vessel formation in the tumor through the administration of medication, Somatom Force can be used to determine specifically at a much earlier stage whether the treatment is working. It can also help to ensure that medication costing several thousand euros per month is deployed more efficiently and so to reduce the overall cost of the treatment.

Typically, long-term CT monitoring is used to identify the correct time to potentially switch treatments. The significantly reduced the cumulated radiation dose with this technology is a great advantage. “This CT system means that medical imaging is no longer restricted to traditional diagnostics,” explained Prof. Schönberg. “As radiologists, we can now work toward the ultimate goal of all medical intervention: The patient’s recovery.”

Early cancer detection at up to 50% lower dose The US National Lung Screening Trial (NLST) screening study conducted in the United States has encouraged a shift of priorities in cancer prevention: The study showed that mortality rates can be reduced by 20% if early lung cancer detection is performed with low-dose CT instead of traditional chest X-rays. Somatom Force is particularly suitable for such early detection examinations due to its previously unattained low dose values. Up to 50% lower than that of earlier high-end CT models, this radiation dose can be attributed to the Turbo Flash mode of Somatom Force and the use of two special spectral filters—selective photon shields, which optimize the X-ray spectrum and thus significantly improve the air/soft-tissue contrast.

Examinations performed at the University Medical Centre Mannheim revealed that dose values of 0.1 mSv for a lung scan could be achieved with the CT system, even in routine clinical situations. “With Somatom Force, there are almost no more contraindications for computed tomography,” said PD Dr. Thomas Henzler, head of cardiothoracic imaging at the University Medical Centre Mannheim.

Another advantage in pulmonary diagnostics is the enlarged field of view (50 cm) of the Turbo Flash Mode on Somatom Force, which covers the entire organ. This extremely quick scan mode with an acquisition rate of nearly 400 mm per second allows the entire thorax to be visualized in approximately one second.

Due to an extremely fast acquisition rate (737 mm/s), if a larger body region is to be scanned, the entire thoracic-abdominal exams can even be performed in just one second. This means that patients may not need to hold their breath. With the Somatom Force, even high heart rates do not lead to disruptive motion artifacts in clinical images, a fact indicated by images taken of a female patient with 90 heartbeats per minute and no medicinal measures to lower her heart rate.

Related Links:

Siemens Healthcare



Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Gas Analyzer
GE SAM
Pediatric Mask
Respire SOFT
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image

Explainable AI Tool Improves Brain Disorder Screening from 4D fMRI

Functional magnetic resonance imaging (fMRI) captures changes in brain activity over time, but the resulting image sequences can be difficult to analyze. Screening for brain disorders requires assessing... Read more

Critical Care

view channel
Image: Liposomes have long been used for gradual drug delivery, with their composition controlling release speed, potency, duration, and potential toxicity. (Image Credit: iStock)

New Drug Delivery System Extends Release of Local Anesthetic for Weeks

Local anesthetics used for nerve blocks often provide pain relief for only a limited period, while perioperative pain can persist much longer. Extending the duration of a nerve block therefore requires... Read more

Surgical Techniques

view channel
Image: Memo 4D Curve preserves the mitral annulus’s natural three-dimensional motion while supporting remodeling and is available in sizes up to 42 mm for a broad range of mitral pathology. (Photo courtesy of Corcym)

First Human Implant Performed With New Open Mitral Annuloplasty Ring

In mitral valve repair, clinicians aim to preserve the mitral annulus’s three-dimensional motion while providing enough support for effective remodeling. Ring preferences vary between open and closed ... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.