Analysis Tool Shows Proton Therapy Less Expensive Than IMRT for Advanced Head and Neck Cancers

By HospiMedica International staff writers
Posted on 18 Sep 2014
The episodic cost of care using intensity-modulated proton therapy (IMPT) in advanced stage head and neck cancer is less expensive than intensity-modulated radiotherapy (IMRT), according to new findings. More...
The new proof-of-concept study uses a cost analysis tool that can be used to outline the value of competing healthcare technologies and treatments.

“This study, while focused on a small sample of patients, for the first time confirms empirically what many oncologists and radiologists believe but has not been fully borne out by research,” says senior author Steven J. Frank, MD, medical director of the center and associate professor of radiation oncology, the Proton Therapy Center at the University of Texas MD Anderson Cancer Center (Houston, USA). “Even though the upfront cost of proton radiation is higher than IMRT, its ability to minimize side effects ultimately results in fewer healthcare dollars. Also, though the study focused on shorter-term complications, we believe it would apply to long-term. This is critically important for head and neck cancer patients, as they’re more likely to be young adults with families and long lives ahead.”

The study, published September 2014 in the journal Oncology Papers, centered on two oropharyngeal cancer patients during the course of 33 daily radiation doses--one patient receiving IMPT, the most advanced type of proton radiation which can spare surrounding healthy tissue from damage, and the other receiving IMRT, which destroys both cancerous and healthy cells. The patients also had weekly chemotherapy treatments. The researchers found that even though the daily cost for proton therapy was about triple the cost of IMRT, the IMRT patients’ outcomes and quality of life measures necessitated additional clinical costs. That these included moderate to severe toxicity, a required feeding tube, nutritional and other supportive care, and weight loss that necessitated revised radiation plans. And lastly, that by the end of the patients’ treatments, the proton therapy costs were 20% less than IMRT.

These findings are based on a model called time-driven activity-based costing (TDABC), a tool that relates the measurement of costs to time—such as the time required to perform each individual medical service. The methodology is being studied across numerous areas at MD Anderson Cancer Center under the leadership of Thomas Feeley, MD, head of the Institute for Cancer Care Innovation and a coauthor of this study.

“This is an important first step in shifting a decades-old conversation strictly about the initial costs of proton therapy to a discussion about value,” said Dr. Frank. “There is a cost-based incentive to think about the value—monetary and in terms of quality of life—of avoiding some of the complications of cancer treatment in the first place.”

Dr. Frank is adding on this research with a randomized clinical trial: he has enrolled nearly 50 patients to date and is planning to recruit a total of 360 patients over the next five years. He also hopes to open the study to other cancer centers in the near future. Dr. Frank anticipates that ongoing results from the study will help inform health policy changes that are ongoing across the United States, including bundled insurance payment initiatives.

Related Links:

University of Texas MD Anderson Cancer Center



Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Desk Aneroid Sphyg
Diagnostix 750D+
New
Breast Imaging Monitor
Barco Coronis Onelook MDMC-32133 32MP
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image

Explainable AI Tool Improves Brain Disorder Screening from 4D fMRI

Functional magnetic resonance imaging (fMRI) captures changes in brain activity over time, but the resulting image sequences can be difficult to analyze. Screening for brain disorders requires assessing... Read more

Critical Care

view channel
Image: Liposomes have long been used for gradual drug delivery, with their composition controlling release speed, potency, duration, and potential toxicity. (Image Credit: iStock)

New Drug Delivery System Extends Release of Local Anesthetic for Weeks

Local anesthetics used for nerve blocks often provide pain relief for only a limited period, while perioperative pain can persist much longer. Extending the duration of a nerve block therefore requires... Read more

Surgical Techniques

view channel
Image: Memo 4D Curve preserves the mitral annulus’s natural three-dimensional motion while supporting remodeling and is available in sizes up to 42 mm for a broad range of mitral pathology. (Photo courtesy of Corcym)

First Human Implant Performed With New Open Mitral Annuloplasty Ring

In mitral valve repair, clinicians aim to preserve the mitral annulus’s three-dimensional motion while providing enough support for effective remodeling. Ring preferences vary between open and closed ... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.