Perioperative Ultrasound Monitoring of Radial Artery Catheter Failure

By HospiMedica International staff writers
Posted on 09 Jun 2015
Using a hand carry ultrasound system, students and staff from the Department of Radiology/Ultrasound and Anesthesiology at Sidney Kimmel Medical College of Thomas Jefferson University recently finished a study of mechanisms related in the cause of radial artery catheter failure. More...


The study was presented at the 2015 WFUMB/AIUM Convention [UMB 41(4S):S125, 2015]. Radial artery catheters (RAC) are commonly used in the emergency department, operating rooms and critical care units of a hospital to accurately monitor the arterial blood pressure and acquire blood samples.

With the use of SonoScape’s S9 ultrasound system (SonoScape Medical corp.; Shenzhen, China), the researchers hoped to discover why RAC fail prematurely and the causes of complications related to RAC clinical use. The clinical trial was designed to determine the causes of RAC failure and to confirm if a low artery diameter to catheter diameter ratio leads to decreased local blood flow and thrombosis.

For this IRB-approved study, 25 patients requiring a RAC for clinical care were enrolled. To evaluate and monitor the RAC insertions as well as blood flow dynamics in the radial and ulnar arteries, the 25 patients were scanned with the S9 ultrasound system with a 12 MHz linear array probe.

They were scanned before RAC insertion, immediately after, and intermittently every two to four hours during the day and every four to six hours during the night (for 24 to 36 hours). By using the S9 ultrasound, they were able to literally see what was happening in the ulnar and radial arteries of the patients.

Using the S9’s grayscale and Doppler technology, measurements were taken of blood flow and the diameters of both the ulnar and radial arteries. Assessments of RAC insertion factors also allowed for measurements for the composite vessel trauma score for respective arteries after insertion. To analyze the data, a paired Student t-test and a Wilcoxon Rank-Sum test were used to compare results. For the purpose of the study, a RAC initial failure and final failure were classified as difficulty/inability to aspirate blood through the RAC or a dampening/loss of the blood pressure waveform.

Throughout the study, a total of 211 ultrasound scans were obtained from the 25 patients using the S9 ultrasound system. From the 25 patients, 21 experienced a RAC initial failure and four patients experienced a RAC final failure. With the S9’s high image clarity, the reasons for RAC failure were easily revealed. Each failed for a different reason: ranging from the catheter being outside of the vessel and in the subcutaneous tissue, the RA catheter tip was against the arterial wall, thrombus on the catheter tip partially/completely obstructed the RA catheter lumen, and thrombus within the RA lumen partially/completely obstructed RA blood flow.

Soon after RA catheter insertion, the RA and UA inner diameters increased from 2.21±0.4 mm to 2.54±0.45 mm and from 1.91±0.44 mm to 2.23±0.48 mm respectively (no significant differences in RA and UA diameters).

For the 24 RACs that did not have a final failure, the median number of cannulation attempts was 9 and the median CVTS was 8.5. Comparatively, the CVTS for the four RACS that developed a final failure was 8.3 and the mean number of blood draws was 5±3.3. Median time to initial dampening of the RA waveform was 5.9 hours in 22 different cases.

By using the S9’s color Doppler, the team was able to measure the velocities in the RA and UA arteries after RAC insertion. In the RA artery, the peak velocity decreased from 56.2±18.7 to 36.6 cm/s after the RAC was inserted. Peak velocity in the UA however, increased from 53.7±19.3 to 63.4±20.5 cm/s after insertion of the RAC. Ultrasound scans also did not indicate a difference in vessel diameter or blood flow velocity when comparing successful RACs to that of the four that developed a final failure; however this may be attributed to the limited number of final failures that were observed.

There was also no difference in velocity patterns or in diameter in the RACs that failed compared to those that did not fail.

The conclusions from this study are threefold. Both the RA and UA experienced significant dilation after RAC insertion. The data suggested that vasodilation and increased blood flow around the catheter may help to prevent thrombosis and protect the function of the arterial catheter. In some patients, the peak blood flow velocity significantly decreased after insertion of a 20 g catheter, especially in RA with a small inner diameter. With the S9’s high-resolution ultrasound imaging abilities, in vivo observations were possible to reveal what caused RAC failure during the patient’s clinical course. Failures consisted primarily of tortuous vascular anatomy and RAC tip obstruction, thrombus formation on the RAC tip, and partial/complete thrombosis of the RA lumen.

Related Links:

SonoScape Medical corp.



Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Immobilization System
Cranial 4Pi Immobilization
Wound Irrigation Solution
Prontosan®
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: MIT researchers have developed a handheld device capable of gently collecting living cells from specific locations to test for ovarian and many other types of cancer. (Photo courtesy of Kripa Varanasi, et al)

Handheld Device Improves Targeted Cell Collection for Early Ovarian Cancer Assessment

High-grade serous ovarian cancer is the most common form of ovarian cancer, and many cases are thought to originate in the fallopian tubes. Because precursor lesions can be microscopic, they are difficult... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.