We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Shearwave Elastography for Evaluating the Liver: Developments

By Dr. James Trotter, Baylor University Medical Ctr.
Posted on 27 Oct 2015
According to the Centers for Disease Control and Prevention, approximately 2.7 million persons in the United States have chronic HCV infection. More...
Assessing the degree of liver damage from the virus is an important step for patients who have a hepatitis C diagnosis, as the results of the assessment will contribute to decisions about treatment. ShearWave Elastography (SWE) offers a noninvasive alternative to biopsy for evaluating liver fibrosis, monitoring the disease, and following up after treatment. At each of these stages, using SWE is a cost-effective way to help avoid biopsy while gleaning the necessary information quickly and without complications (including pain and discomfort for the patient).

The technology
SWE is a form of ultrasound elastography that uses fast-moving shear waves to determine tissue stiffness. It is distinguished from strain elastography in that shearwave elastography does not depend on an expert user palpating the tissue to achieve optimal results; some SWE platforms automate the sonic “push” that generates these waves, which are then captured at speeds much greater than conventional ultrasound. SuperSonic Imagine (Aix-en-Provence, France), which pioneered the technique, received FDA clearance for its real-time, color-coded quantification of tissue elasticity in kilopascals (kPa), a display superimposed on a B-mode image for anatomical correlation.

Rise in demand
Studies have demonstrated the effectiveness of SWE for applications including breast imaging, imaging of the thyroid and prostate, and, more recently, in MSK diagnosis and monitoring as well. The clinical advantages of SWE for evaluating the liver have been the subject of larger studies over more time. These studies constitute a body of evidence that the World Federation for Ultrasound in Medicine and Biology (WFUMB) used, along with practical advice from its contributing radiologist authors, to inform their chapter in the Guidelines and Recommendations for Clinical Use of Ultrasound Elastography (2015) on the use of elastography to assess and manage liver diseases. These Guidelines are timely in relation to two factors: the rise of liver disease globally, and the advances in treatment for hepatitis C specifically.

Newly developed oral medications for hepatitis C are simpler to take, work more quickly, have fewer side effects, and have dramatically improved outcomes: with the new treatments, approximately 90% of hepatitis C patients are cured of the virus. The high cost of these oral medications remains an issue. Still, their efficacy and greatly reduced side effects have simplified the decision to treat the disease, which used to be a complex weighing of trade-offs for hepatologists. In 2014 the Centers for Medicaid and Medicare Services (CMS) made the determination to cover HCV screenings for patients at “high risk” for the disease, increasing efforts to uncover asymptomatic cases before they do damage. Greater outreach about and surveillance of the disease have thus dovetailed with the advances in the available medications. The ease of exam, accuracy of the results, and noninvasive nature of SWE make it a highly useful tool for evaluation in this new landscape.


Biopsies vs. SWE
While biopsies of the liver do not carry large risks of morbidity (and pose even less risk of mortality), they are costly, time-consuming, and their common complications are still burdensome. Over 25% of patients undergoing biopsy experience pain, and the procedures take several hours. An SWE scan is painless and can be done in less than two minutes in a radiologist’s office. Further, SWE can sometimes be used to circumvent biopsy’s sampling limitations; ultrasound-guided imaging technology can help zero in on areas of interest in real time rather than risk the need for follow-ups due to sampling variability or error (the liver is a large organ). Eliminating additional biopsies decreases the patient’s time in the clinic, which can direct resources to those who need them and improve clinical throughput.

SWE for follow-up
Even with 90% of hepatitis C patients being cured of the virus, the need for follow-up persists. The progress of those patients must be established, which in the past also required biopsies. SWE can frequently substitute for this traditional use of biopsy, too. Additionally, with some of the more legible displays, SWE can visually demonstrate to patients the progress they’ve made. Comparing a current scan with one called up from an earlier visit can thus inform and educate the patient about their health.

i "http://www.cdc.gov/hepatitis/hcv/cfaq.htm"
ii "http://www.ncbi.nlm.nih.gov/pubmed/25800942"
iii "http://www.niaid.nih.gov/news/newsreleases/2015/Pages/HepatitisCTripleDrug.aspx"
iv "https://www.cms.gov/medicare-coverage-database/details/nca-decision-memo.aspx?NCAId=272"
v "http://hcvadvocate.org/hepatitis/factsheets_pdf/Biopsy.pdf"

Related Links:
Baylor University Medical Center of Dallas



Gold Member
Neonatal Heel Incision Device
Tenderfoot
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Hypodermic Syringe
SurTract™ Safety Syringe
Multi-Chamber Washer-Disinfector
WD 390
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: MIT researchers have developed a handheld device capable of gently collecting living cells from specific locations to test for ovarian and many other types of cancer. (Photo courtesy of Kripa Varanasi, et al)

Handheld Device Improves Targeted Cell Collection for Early Ovarian Cancer Assessment

High-grade serous ovarian cancer is the most common form of ovarian cancer, and many cases are thought to originate in the fallopian tubes. Because precursor lesions can be microscopic, they are difficult... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.