We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Radiation Detector Plate Improves Cancer Radiotherapy

By HospiMedica International staff writers
Posted on 14 Mar 2016
A prototype detector plate placed in the radiation path (before the X-ray beam hits the patient) records a real-time map of the intensity of the radiotherapy (RT) beams.

Developed by researchers at the University of Wollongong (UOW; Australia), the MagicPlate-512 (MP512) detector consists of a silicon monolithic diode array sandwiched between plastic sheets less than 1-mm thick, which measures the radiation dose during treatment with millisecond by millisecond precision. More...
A proprietary algorithm determines the actual dose reaching the patient, based on the measured intensity of the X-ray distribution in the beam. This can then be compared to the planned dose; if a mismatch exists, the RT could be automatically and immediately stopped.

The MP512 detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of resin to preserve it from moisture and chemical contamination, and to protect the bonding wires. The array contains 512 0.5×0.5 mm2 pixels with a pitch of 2 mm. It has been tested and validated in a simulated environment using different X-ray beam energies that are commonly used to treat cancer patients. The researchers found the plate did not interfere with the quality of RT and accurately recorded in real-time the transmission of the radiation beam.

“Current procedures typically involve a test on a plastic dummy before the patient is treated, to verify the equipment is delivering the dose according to the oncologist’s treatment plan calculations,” said Ziyad Alrowaili, MSc, who developed the plate as part of his PhD thesis. “This is an intensive task and an additional workload for the medical physicist. And despite the high levels of quality assurance, the clinician can’t routinely measure the dose accuracy directly during the patient treatment delivery and independently of the linear accelerator settings.”

“A single patient treatment plan may contain thousands of parameters defining the variables involved, and this complexity makes it imperative that processes are in place to check and verify the X-ray equipment delivers the dose accurately,” added Martin Carolan, MD, director of radiation oncology medical physics at Illawarra Shoalhaven Local Health District (ISLHD; Australia). “There are many layers of safeguards already in place to reduce the risk to the patient, but the concept of measuring the radiation dose distribution every day as it is delivered to the patient is elegant and appealing.”

Related Links:

University of Wollongong
Illawarra Shoalhaven Local Health District



Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Biochip Array Technology
Evidence MultiSTAT Drugs of Abuse Urine Multiplex Panel
Monitor/Defibrillator
Zenix
Pediatric Mask
Respire SOFT
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Surgical Techniques

view channel
Image: Graphical Abstract (Aoibhin M. Sheedy et al., A replenishable peritoneal implant for localized delivery and peritoneal fluid sampling in ovarian cancer, Device (2026). DOI: 10.1016/j.device.2026.101050)

New Implant Provides Sustained Localized Therapy for Ovarian Cancer

Ovarian cancer is often diagnosed at advanced stages because symptoms such as bloating, pain, and pelvic pressure are nonspecific. Standard care relies on surgery and systemic therapy, yet tools for targeted... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.