We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Radiation Detector Plate Improves Cancer Radiotherapy

By HospiMedica International staff writers
Posted on 14 Mar 2016
A prototype detector plate placed in the radiation path (before the X-ray beam hits the patient) records a real-time map of the intensity of the radiotherapy (RT) beams.

Developed by researchers at the University of Wollongong (UOW; Australia), the MagicPlate-512 (MP512) detector consists of a silicon monolithic diode array sandwiched between plastic sheets less than 1-mm thick, which measures the radiation dose during treatment with millisecond by millisecond precision. More...
A proprietary algorithm determines the actual dose reaching the patient, based on the measured intensity of the X-ray distribution in the beam. This can then be compared to the planned dose; if a mismatch exists, the RT could be automatically and immediately stopped.

The MP512 detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of resin to preserve it from moisture and chemical contamination, and to protect the bonding wires. The array contains 512 0.5×0.5 mm2 pixels with a pitch of 2 mm. It has been tested and validated in a simulated environment using different X-ray beam energies that are commonly used to treat cancer patients. The researchers found the plate did not interfere with the quality of RT and accurately recorded in real-time the transmission of the radiation beam.

“Current procedures typically involve a test on a plastic dummy before the patient is treated, to verify the equipment is delivering the dose according to the oncologist’s treatment plan calculations,” said Ziyad Alrowaili, MSc, who developed the plate as part of his PhD thesis. “This is an intensive task and an additional workload for the medical physicist. And despite the high levels of quality assurance, the clinician can’t routinely measure the dose accuracy directly during the patient treatment delivery and independently of the linear accelerator settings.”

“A single patient treatment plan may contain thousands of parameters defining the variables involved, and this complexity makes it imperative that processes are in place to check and verify the X-ray equipment delivers the dose accurately,” added Martin Carolan, MD, director of radiation oncology medical physics at Illawarra Shoalhaven Local Health District (ISLHD; Australia). “There are many layers of safeguards already in place to reduce the risk to the patient, but the concept of measuring the radiation dose distribution every day as it is delivered to the patient is elegant and appealing.”

Related Links:

University of Wollongong
Illawarra Shoalhaven Local Health District



Gold Member
Neonatal Heel Incision Device
Tenderfoot
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
New
Breast Imaging Monitor
Barco Coronis Onelook MDMC-32133 32MP
Patient Preoperative Skin Preparation
BD ChloraPrep
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: MIT researchers have developed a handheld device capable of gently collecting living cells from specific locations to test for ovarian and many other types of cancer. (Photo courtesy of Kripa Varanasi, et al)

Handheld Device Improves Targeted Cell Collection for Early Ovarian Cancer Assessment

High-grade serous ovarian cancer is the most common form of ovarian cancer, and many cases are thought to originate in the fallopian tubes. Because precursor lesions can be microscopic, they are difficult... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.