We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Supercomputers Help Estimate Astronauts Radiation Risk

By HospiMedica International staff writers
Posted on 19 Apr 2018
A new study reveals that a space vehicle with relatively minimal shielding and a high inclination polar orbit could expose astronauts to high exposures of cosmic radiation and solar particle events.

Researchers at Texas A&M University (TAMU; College Station, TX, USA), the U.S. More...
National Aeronautics and Space Administration (NASA; Houston, USA), and the Mayo Clinic Arizona (Scottsdale, USA) investigated potential radiation risks facing astronauts that would have operated the Manned Orbiting Laboratory (MOL), a mission planned by NASA in the 1960’s, but which never actually flew. Mission documents were recently declassified.

The MOL was conceived as an experimental laboratory for human spaceflight, but was recast as a secret reconnaissance platform in 1965 during the height of the Cold War. The vehicle would have travelled in low-earth orbit and passed repeatedly over the northern and southern polar regions to better spy on the Soviet Union. In August 1972, three years after the MOL mission planning was discontinued due to the emergence of cheaper, unmanned satellites, the Earth experienced a historically large solar particle event. The researchers explored how typical radiation and a solar flare from would have impacted MOL pilots.

They focused on radiation from two sources: solar particle events (SPEs) and galactic cosmic rays (GCRs). The researchers first modeled the MOL's orbit profile, the space weather and geomagnetic forces from those years, and the particle and heavy ion transport that such a trajectory would have encountered. Then, using a supercomputer requiring 150,000 computational hours, they found that under normal conditions, the MOL crew would have endured 113.6 millisievert (mSv) to their skin and 41.6 mSv to blood forming organs during a 30-day flight, well within the exposure limits for NASA astronauts.

However, during the "worst-case scenario" of the 1972 solar storm, their skin would have been exposed to 1,770 mSv, while their organs would have experienced 451 mSv, toxic doses of radiation. Based on animal studies, they concluded that such exposure would have caused nausea, vomiting, fatigue, and possibly skin burns to crew. Without rapid instigation of medical countermeasures, the risks could have been even more severe, affecting both short and long-term human health. The study was published on April 4, 2018, in npj Microgravity.

“Given the intended future of human spaceflight, with efforts now to rapidly expand capabilities for human missions to the moon and Mars, there is a pressing need to improve upon the understanding of the space radiation risk,” said lead author Jeffery Chancellor, MSc, of the TAMU department of physics and astronomy. “I think the research will have a huge impact for commercial space flight. It gives some insight to people who are trying to come up with ideas for orbiting hotels, or to SpaceX or Virgin Galactic who want to do tourist flights, in terms of what they have to address in order to protect the crew and customers.”

Accelerated ions in cosmic radiation interact differently with objects and people. While X-rays can be blocked by lead shields, GCR ions can become more dangerous when interacting with metals, generating secondary particles that have biological effects, such as an accelerated development of atherosclerosis, rapid progression of advanced aortic root lesions, reduced lesional collagen, and intima media thickening of the carotid arteries. Space travel also affects other organs; the heart, for example, changes shape and becomes more spherical.

Related Links:
Texas A&M University
U.S. National Aeronautics and Space Administration
Mayo Clinic Arizona

Gold Member
Blood Gas Analyzer
i-Check200
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Radiofrequency Generator
GX1
Tourniquet System
heidi– mein Tourniquet
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.