We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Philips Healthcare

Operates in Diagnostic Imaging Systems, Patient Care and Clinical Informatics, Customer Services, and Home Healthcare... read more Featured Products: More products

Download Mobile App




Augmented-Reality Enhances Surgical Navigation Technology

By HospiMedica International staff writers
Posted on 25 Jan 2017
A combination of three-dimensional (3D) X-ray and advanced optics provides surgeons with augmented-reality imaging during spine, cranial, and trauma surgical procedures.

The Royal Philips augmented-reality surgical navigation technology is designed to help surgeons perform image-guided open and minimally invasive spine surgery in a hybrid operating room (OR). More...
Due to the inherently reduced visibility of the spine and other structures during such procedures, surgeons rely on real-time imaging and navigation solutions in order to guide their surgical tools and implants. The same is true for minimally invasive cranial surgery and surgery on complex trauma fractures.

The new Philips technology adds additional capabilities to the company’s low-dose X-ray system, using high-resolution optical cameras mounted on the X-ray flat panel detector (FPD) to image the surface of the patient. It then combines the external view captured by the cameras and the internal 3D view of acquired by the X-ray system to construct an augmented-reality view of the patient’s external and internal anatomy, improving procedural planning, surgical tool navigation, and implant accuracy, as well as reducing procedure times.

The first pre-clinical study on the technology was undertaken as a collaboration between Philips, Karolinska University Hospital, Cincinnati Children's Hospital Medical Center, and eight other medical centers. The results showed the technology to be significantly better with respect to overall accuracy (85%), when compared to pedicle screw placement without the technology (64%). The study was published in the November 2016 issue of Spine.

“This new technology allows us to intraoperatively make a high-resolution 3D image of the patient’s spine, plan the optimal device path, and subsequently place pedicle screws using the system’s fully-automatic augmented-reality navigation,” said study co-author Stefan Skúlason, MD, of Landspitali University Hospital (Reykjavik, Iceland). “We can also check the overall result in 3D in the OR without the need to move the patient to a CT scanner. And all this can be done without any radiation exposure to the surgeon and with minimal dose to the patient.”


Gold Member
Neonatal Heel Incision Device
Tenderfoot
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Medical Examination & Procedure Light
Vega 80
Radiofrequency Generator
GX1
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.