Radioactive Teletherapy System Destroys Breast Cancer

By HospiMedica International staff writers
Posted on 08 May 2019
An innovative cobalt (Co60) stereotactic radiotherapy system (SRS) immobilizes the breast in order to provide high levels of accuracy during treatment planning and delivery.

At the core of the Xcision Medical Systems (Columbia, MD, USA) GammaPod is a two-layer, vacuum-assisted positioning cup that immobilizes the breast during treatment, which is designed to reproducibly hold the breast in place and provide an accurate reference frame to match the tumor with the coordinate system of the irradiation unit. More...
The cup consists of a rigid reusable outer cup with an imbedded stereotactic frame and a thin inner cup joined together by a silicone flange at the chest side. A mild negative pressure is applied between the inner and outer cups, causing the skin of the breast to press against the inner cup, securing it in place.

A patient loader then lifts and rotates the patient, positioned on a treatment couch, from a standing to a prone position, towards a portal within which the breast immobilization cup is affixed. Once in position, the hemispherical irradiation unit, which holds 36 rotating radioactive Co60 sources, a dynamic collimator system, and a hemi-elliptical-sphere treatment space, delivers thousands of focused beams of radiation towards the tumor, thus minimizing the dose to the surrounding healthy tissues in the breast, heart, and lungs. The irradiation unit is controlled by a computerized treatment control system.

A treatment planning system designed specifically for breast SRS using the GammaPod places imaging studies and scans within the stereotactic localization frame coordinate system through a proprietary registration process. The pre-procedural planning optimizes the dynamic trajectory of the RT foci using different spot sizes to realize the prescribed doses to the target volume while minimizing radiation exposure to the surrounding tissues and structures, ensuring accurate dose calculation of the optimized plan and providing dosimetric indices for review.

“The ability of GammaPod to noninvasively deliver conformal radiation doses to only the affected area of the breast with the precision of stereotactic radiotherapy could certainly de-escalate care and reduce the burden of today's protracted treatments on patients,” said Professor Cedric Yu, DSc, founder and CEO of Xcision. “One day we'll be able to neutralize a tumor with a high dose of focused radiation instead of removing it with a scalpel. This approach would spare patients the negative side effects of surgery and prolonged radiation treatments, significantly improving their quality of life.”

Co60 radioactive decay releases two gamma rays with an average energy of approximately 1.25 MeV, and is essentially identical to an x-ray emission. Examples of other SRS units containing multiple Co60 sources include the Elekta Gamma Knife (with 192 sources), and the American Radiosurgery Rotating Gamma System.

Related Links:
Xcision Medical Systems


Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Desk Aneroid Sphyg
Diagnostix 750D+
Monitor/Defibrillator
Zenix
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: 123RF

AI-Enhanced Handheld Ultrasound Improves Carotid Plaque Detection

Handheld ultrasound can miss small or faint carotid plaque, creating uncertainty in community screening. This gap makes it harder for frontline clinicians to decide who needs confirmatory imaging, closer... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.