We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




New Photon-Counting CT Technique Diagnoses Osteoarthritis Before Symptoms Develop

By HospiMedica International staff writers
Posted on 29 Oct 2024

X-ray imaging has evolved significantly since its introduction in 1895. More...

This technique is known for capturing images quickly, making it ideal for emergency situations; however, it does not provide adequate soft tissue contrast and struggles to differentiate the imaging signal from the disease site from that of intrinsic structures like bones. In imaging, visualization is particularly critical for diseases such as osteoarthritis, a degenerative joint condition often referred to as wear-and-tear arthritis. Osteoarthritis can advance without noticeable symptoms until it reaches an advanced and irreversible stage. Early intervention could alleviate symptoms and enhance quality of life if tools for early diagnosis and continuous disease monitoring were available. Now, a new technological breakthrough brings back traditional black and white diagnostic images of X-rays and traditional computed tomography (CT) scans into technicolor.

Researchers at Penn State (University Park, PA, USA) have developed novel contrast agents that target two proteins associated with osteoarthritis. By marking these proteins with newly designed metal nanoprobes, the researchers can utilize advanced imaging techniques known as “K-edge” imaging or photon-counting CT to simultaneously track distinct biological processes in color, which together provide greater insight into the disease's progression than traditional imaging methods. This work, conducted in rats with potential implications for humans, enables researchers and clinicians to visualize previously hidden processes in color and detect signs of the disease long before the development of clinical symptoms.

The photon-counting CT scanner can detail the same bone, muscle, and fat structures that conventional CT scanners capture but offers a much broader capability to separate various components at a higher resolution and in specific colors. This scanner identifies materials with unique K-edge properties, which refers to how electrons in a material absorb energy. Electrons reside in a K-shell, which surrounds the nucleus of an atom. When energy is absorbed from photons—particles of light—the electrons can move to higher energy shells. If the atom reaches a specific energy absorption limit, it emits a flash of light. The researchers can program the scanner to detect that particular light emission, referred to as the K-edge. If a material with a distinct K-edge identity targets a specific protein, the scanner can then track that protein's activity.

The team designed two K-edge metal nanoprobes composed of praseodymium and hafnium. These probes are aimed at two proteins found in cartilage tissue: aggrecan and aggrecanase, respectively. Aggrecan, which contributes to the structure and weight-bearing capacity of cartilage, is abundant in healthy joints and in the early stages of osteoarthritis. In contrast, aggrecanase, which cleaves aggrecan and diminishes cartilage function, is prevalent in the later stages of osteoarthritis. As the disease progresses, the ratio of these proteins shifts, providing metrics to monitor disease status. The researchers employed the photon-counting CT scanner to observe how this ratio changed as the disease advanced in an animal model. They corroborated their findings with additional imaging and experimental validation, with their results published in Advanced Science.

“This high-resolution, K-edge-based imaging approach could potentially be used to image multiple biological targets, thus enabling disease progression tracking over time by measuring the ratio of protein expression,” said corresponding author Dipanjan Pan, the Dorothy Foehr Huck & J. Lloyd Huck Chair Professor in Nanomedicine and professor of materials science and engineering and of nuclear engineering at Penn State. “The approach can be particularly beneficial in skeletal disease diagnoses since the progression of cartilage degradation is highly variable among patients and the ratio information from the protein markers could provide crucial information about the stage of the disease.”


Gold Member
12-Channel ECG
CM1200B
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Hypodermic Syringe
SurTract™ Safety Syringe
Monitor/Defibrillator
Zenix
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: Adobe Stock

Emergency Department Campaign Reduces CT Use Without Identified Missed Injuries

Unnecessary head and cervical spine computed tomography (CT) in low-risk trauma patients exposes them to avoidable radiation, prolongs emergency department stays, and increases healthcare costs.... Read more

Surgical Techniques

view channel
Image: Researchers developed a handheld photothermal mid-infrared spectroscopic imaging (MIRSI) system that measures just 8 square inches. Probe light from a visible (red) diode laser and pump light from a modulated quantum cascade laser (QCL) are coupled into optical fibers and delivered to a flexible, handheld imager (blue dashed box). The beams are combined at a short-pass dichroic mirror and focused onto the sample using an off-axis parabolic mirror (OAP). (Image Credit:Rohith Reddy, University of Houston)

Handheld Infrared Imaging Device Supports Tumor Margin Assessment During Surgery

Accurately determining tumor margins during surgery remains challenging. Frozen-section pathology takes time and can miss residual disease, potentially leading to repeat surgery and delayed therapy.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.