We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
Sekisui Diagnostics UK Ltd.

Download Mobile App





COVID-19 Diagnostic Skin Test to Measure SARS-CoV-2 Exposure and T Cell Immunity

By HospiMedica International staff writers
Posted on 09 Feb 2021
Print article
Illustration
Illustration
A diagnostic skin test currently under development could have multiple potential uses, including functional measurement of T Cell immunity to SARS-CoV-2, COVID-19 diagnosis and public health surveillance; and an endpoint for COVID-19 vaccine trials.

Tonix Pharmaceuticals Holding Corp. (Chatham, NJ, USA) has received a written response from the US Food and Drug Administration (FDA) to a Type B pre-investigational new drug (IND) meeting package describing its technology and plans to develop a diagnostic skin test, TNX-2100 (SARS-CoV-2 epitope peptide mixtures for intradermal administration), to measure the delayed-type hypersensitivity (DTH) reaction to SARS-CoV-2 (CoV-2).

TNX-2100 is a test comprising three different mixtures of synthetic peptides (TNX-2110, -2120 and -2130), which are designed to represent different protein components of the CoV-2 virus. TNX-2110 (CoV-2 multi-antigen peptides) represents multiple proteins from CoV-2. TNX-2120 (CoV-2 spike peptides) represents only the spike protein. TNX-2130 (CoV-2 non-spike peptides) represents non-spike proteins. Each of these three tests is expected to be administered as part of the same procedure, at separate locations on the forearm, and each is expected to elicit a DTH response after approximately 48 hours in individuals with pre-existing T cell immunity to peptides in that mixture. Individuals who have been infected by or exposed to CoV-2 would be expected to respond to all three mixtures. In contrast, a successfully vaccinated individual who has not been exposed or infected by CoV-2 would be expected to respond only to TNX-2120 (CoV-2 spike peptides), since the currently available vaccines only encode spike protein. In the planned clinical protocol for testing TNX-2100, positive skin test controls will be used to confirm that study participants have intact T cell immunity and are not immunodeficient.

TNX-2100 is designed to be administered as a skin test. A thin gauge needle is used to apply the three separate peptide mixtures into the skin, or intradermally, on the inner surface of the forearm between the wrist and the elbow. The test may be administered in a variety of settings: ranging from a doctor’s office to a remote outpost without running water or in inclement or extreme weather. In a typical positive test, the skin surrounding the injection site is expected to become red, raised and hardened, or “indurated”, after approximately 48 hours. Induration above a threshold level would signify a positive result and the diameter of the induration would indicate the amount of T cell immunity to the test peptides. DTH skin test responses are believed to reflect functional in vivo immunity. Clinical trials are expected to correlate skin test results with clinical history to inform estimates about the sensitivity and specificity of the test as a marker of T cell immunity in individuals pre- and post-COVID-19 vaccination, who are recovered from COVID-19, and some with active CoV-2 infection.

There currently is no standardized laboratory test available to measure T cell immune responses to CoV-2. T cell immunity to CoV-2 persists longer than antibody immunity, is sometimes present in the absence of a measurable antibody response and is believed to provide an important element of protection against serious COVID-19 illness after infection with CoV-2. The only currently available methods to detect T cell immunity to CoV-2 require expensive, multi-step sample preparation and in vitro T cell stimulation in highly specialized laboratories using methods that have not been amenable to standardization. When fully developed, the TNX-2100 skin test is expected to provide clinicians, patients, employers and public health officials with information of potential diagnostic, safety and predictive significance in a timely and cost-effective manner, including the durability of immune responses in vaccinated, convalescent and exposed individuals, clusters, workplaces and populations.

“We believe TNX-2100 has the potential to measure T cell immunity to CoV-2 and therefore serve as an aid to COVID-19 diagnosis to support patient care, public health surveillance and vaccine trials,” said Seth Lederman, M.D., Tonix’s President and Chief Executive Officer. “Our proposed skin test has the potential to serve as: 1) a biomarker for cellular immunity and protective immunity; 2) a method to stratify participants in COVID-19 vaccine trials by immune status; 3) an endpoint in COVID-19 vaccine trials, and 4) a biomarker of durability of vaccine protection.”

Related Links:
Tonix Pharmaceuticals Holding Corp.

Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Ceiling-Mounted Digital Radiography System
Radiography 5000 C

Print article

Channels

Surgical Techniques

view channel
Image: Computational models can predict future structural integrity of a child’s heart valves (Photo courtesy of 123RF)

Computational Models Predict Heart Valve Leakage in Children

Hypoplastic left heart syndrome is a serious birth defect in which the left side of a baby’s heart is underdeveloped and ineffective at pumping blood, forcing the right side to handle the circulation to... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.