Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
IBA-Radcal

Download Mobile App




Smartphones Assist Remote Diagnosis of Acute Appendicitis

By HospiMedica International staff writers
Posted on 11 Dec 2009
Special software allows viewing of raw clinical image data in full resolution, allowing acute appendicitis to be accurately diagnosed from a remote location by a radiologist using an iPhone. More...


Researchers at Johns Hopkins University (JHU, Baltimore, MD, USA) and the University of Virginia (Charlottesville, CT, USA) performed abdomen and pelvis computerized tomography (CT) studies on 25 patients with pain in the right lower abdomen. All patients had either surgical confirmation of the diagnosis of acute appendicitis, or follow-up clinical evaluation confirming no acute appendicitis. Each study was viewed by five blinded radiologists on a handheld device (iPhone 3G), equipped with OsiriX open source mobile medical image viewing software. The studies were evaluated for the ability to find the appendix, the maximum appendiceal diameter, presence of an appendicolith, periappendicial stranding and fluid, abscess formation, and a binary assessment of the diagnosis of acute appendicitis. The studies were also compared to a faculty-read of the study as performed on a dedicated picture archiving and communication system (PACS) workstation.

The results showed that 15 of the 25 patients were correctly identified as having acute appendicitis on 74 (99%) of 75 interpretations, with one false negative; there were no false positive readings. In eight of the 15 patients who had appendicitis, calcified deposits within the appendix were correctly identified in 88% of the interpretations. All 15 patients had signs of inflammation near the appendix that were correctly identified in 96% of interpretations, and 10 of the 15 had fluid near the appendix, which was correctly identified in 94% of the interpretations. Three abscesses were correctly identified by all five readers. However, handheld device measurements of the appendix averaged almost one millimeter larger than measurements on the PACS workstation, suggesting that appedendical diameter should not be used as the sole basis for diagnosis. The study results were presented at the annual meeting of the Radiological Society of North America (RSNA), held during November-December 2009 in Chicago (IL, USA).

"The iPhone interpretations of the CT scans were as accurate as the interpretations viewed on dedicated PACS workstations,” said lead author Asim Choudhri, M.D., of the division of neuroradiology at JHU. "The scans can be read in full resolution with very little panning, and the software allows the reader to zoom and adjust the contrast and brightness of the image. The radiologist is evaluating actual raw image data, not snapshots.”

The researchers concluded that remote viewing of studies may be feasible for emergent consultation to expedite emergency room care when consultation with a specialist is needed, which could be of particular benefit for subspecialist consultation for on-call residents.

Related Links:

Johns Hopkins University
University of Virginia



Gold Member
Blood Gas Analyzer
i-Check200
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Surgical Dressing
ALLEVYN Ag+ SURGICAL
Patient Monitoring System
AlarmSense
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Patient Care

view channel
Image: A view inside the custom virtual reality environment used in the study: a calm room with a teddy bear, soft colors and large windows looking out over the sea. (Image Credit: Walaa S. Abu Rukbah et al., Virginia Commonwealth University; CC-BY 4.0, https://creativecommons.org/licenses/by/4.0/)

Virtual Reality Program May Reduce Anxiety Before Pediatric Surgery

Presurgery anxiety affects an estimated 50% to 75% of children undergoing surgery and can complicate anesthesia induction, increase postoperative pain, and prolong recovery. Sedation is often used to manage... Read more

Point of Care

view channel
Image: Jessica Ramella-Roman, professor of biomedical engineering at Florida International University, holding the PPRIM (Portable Preterm Imaging) device designed to detect early signs of preterm labor risk. (Photo courtesy of Florida International University)

Handheld Imaging Device May Help Identify Preterm Birth Risk Earlier

Preterm birth, defined as delivery before 37 weeks of pregnancy, can lead to serious neonatal complications, including neurological, developmental, and respiratory problems. However, identifying pregnancies... Read more

Business

view channel
Image: Stryker has acquired ZuriMED, adding the FiberLocker System, a rotator cuff augmentation technology designed to strengthen repairs, to its Sports Medicine portfolio. (Photo courtesy of ZuriMED)

Stryker Completes Acquisition to Broaden Shoulder Surgery Offerings

Stryker (Portage, MI, USA) has completed its acquisition of ZuriMED (Zurich, Switzerland), a privately held developer of the FiberLocker System, expanding its Sports Medicine portfolio with a commercialized... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.