3D Printing Aids Surgical Separation of Siamese Twins

By HospiMedica International staff writers
Posted on 13 Dec 2015
A new study describes how computerized tomography (CT) imaging and three-dimensional (3D) printing helped plan the surgical separation of conjoined twins. More...


In the study, researchers at Texas Children's Hospital (Houston, USA) described a new technique they used to surgically separate conjoined twins from Lubbock (TX, USA) born in April 2014, who were connected from the chest all the way down to the pelvis. To prepare for the separation surgery, the researchers performed volumetric CT imaging with a 320-detector scanner, administering intravenous contrast separately to both twins to enhance views of vital structures and help plan how to separate them to ensure survival of both children.

They also used a technique known as target mode prospective electrocardiogram (ECG) gating to freeze the heart and get a more detailed view of the cardiovascular anatomy, while keeping the radiation exposure low. The CT imaging results were then printed as a color-coded physical 3D model with skeletal structures and supports made in hard plastic resin, and soft organs built from a rubber-like material. The models were designed so that they could be assembled together and separated during the surgical planning process.

The CT scans revealed that the babies' hearts were in the same cavity, but were not fused. They also revealed the existence of a “plane of separation” of the joined liver. To assist separation, the liver was printed separately, with major blood vessels depicted in white for better visibility. The surgical team then underwent an exhaustive preparation process leading up to actual surgery, performed on February 17, 2015, by a team of more than 26 clinicians, including 12 surgeons, 6 anesthesiologists, and 8 surgical nurses. The study was presented at the Radiological Society of North America (RSNA) annual meeting, held during November-December 2015 in Chicago (IL, USA).

“The surgeons found the landmarks for the liver, hearts and pelvic organs just as we had described; the concordance was almost perfect,” said lead author and study presenter Rajesh Krishnamurthy, MD, chief of radiology research and cardiac imaging at Texas Children's Hospital. “The 3D model also served another important function—helping the twins' parents, Elysse and John Eric Mata, understand the process. They said 'for the first time, we understand what is going to happen with our babies.’”

Related Links:

Texas Children's Hospital
3D model of conjoined twins – video



Gold Member
12-Channel ECG
CM1200B
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Digital Radiography System (Ceiling Free)
Digix CF Series
Syringe Pump
SP50 Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie MellonImage: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie Mellon University)University)

Portable Artificial Lung Technology Could Reshape Care for Chronic Lung Disease

Chronic lung disease can leave patients dependent on prolonged mechanical ventilation or awaiting transplantation, both of which carry substantial morbidity and healthcare costs. Ventilatory support may... Read more

Surgical Techniques

view channel
Image Credit: 123RF

Needle-Free Intrauterine Anesthesia Technique Reduces Pain During IUD Insertion

Pain during intrauterine device (IUD) placement often deters women from choosing this long-acting contraception. Avoiding or undertreating procedural pain can reduce uptake and satisfaction with effective... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.