Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
IBA-Radcal

Download Mobile App




Brain Mapping Tool Identifies Diseased Tissue

By HospiMedica International staff writers
Posted on 07 Jun 2017
A new device to map the brain during surgery provides higher resolution neural readings than existing tools used in the clinic and could enable doctors to perform safer, more precise brain surgeries.

Developed by researchers at the University of California, San Diego (UCSD, USA), Massachusetts General Hospital (MGH; Boston, USA), and other institutions, the device is an improved version of an electrocorticography electrode grid, which takes advantage of the electrochemical properties of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). More...
Using PEDOT:PSS allows the new electrode grid to be about a thousand times thinner than current clinical electrode grids.

The PEDOT:PSS microelectrode arrays is just 6 micrometers thick (versus several millimeters in current grids), which allows it to conform better to the intricately curved surface of the brain and obtain better readings. The new electrode grid also contains a much higher density of electrodes, since they can be spaced 25 times closer than those in current clinical electrode grids, enabling detection of changes in amplitude across pial surface distances as small as 400 µm, resulting in higher resolution recordings. The researchers also conducted several clinical tests.

In one test, the researchers performed background readings of a patient's brain waves both awake and unconscious. The PEDOT:PSS electrode grid identified normal functioning areas of the brain versus where the seizure areas with more detailed and higher resolution readings than the clinical electrode grid. Other tests that monitored the brain activity of patients performing cognitive tasks showed that both the PEDOT:PSS and standard electrode grids could differentiate between visual and audio inputs. The study was published on May 12, 2017, in Advanced Functional Materials.

“By providing higher resolution views of the human brain, this technology can improve clinical practices and could lead to high performance brain machine interfaces,” said senior author Professor Vikash Gilja, PhD, of the department of engineering at UC San Diego. “These electrodes occupy minuscule volumes; imagine Saran Wrap, but thinner. And we demonstrate that they can capture neural activity from the human brain at least as well as conventional electrodes that are orders of magnitude larger.”

Related Links:
University of California, San Diego
Massachusetts General Hospital


Gold Member
Blood Gas Analyzer
i-Check200
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Syringe Pump
SP50 Series
Breast Imaging Monitor
Barco Coronis Onelook MDMC-32133 32MP
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image Credit: Shutterstock

Explainable AI Examines Sepsis Mortality Risk and Emergency Care Delays

Preventing sepsis-related deaths in emergency departments (EDs) remains challenging because patient deterioration can result from multiple rapidly evolving and interconnected factors. These include triage... Read more

Critical Care

view channel
Image: CapWear uses the natural pressure applied and released by the foot during walking to replicate the process used in conventional capillary refill assessments (Image Credit: Pohang University of Science and Technology)

Smart Footwear Estimates Capillary Refill Time for Peripheral Perfusion Monitoring

Peripheral perfusion reflects how effectively blood reaches the body’s extremities and is commonly assessed in hospitals by measuring capillary refill time. However, repeated monitoring during daily activities... Read more

Health IT

view channel
Image Credit: Shutterstock

Telemonitoring Program Improves Quality of Life After Heart Failure Discharge

Heart failure is a chronic condition associated with high mortality, frequent hospitalizations, and reduced quality of life. Patients face particularly high risks of readmission and death after discharge,... Read more

Point of Care

view channel
Image: Jessica Ramella-Roman, professor of biomedical engineering at Florida International University, holding the PPRIM (Portable Preterm Imaging) device designed to detect early signs of preterm labor risk. (Photo courtesy of Florida International University)

Handheld Imaging Device May Help Identify Preterm Birth Risk Earlier

Preterm birth, defined as delivery before 37 weeks of pregnancy, can lead to serious neonatal complications, including neurological, developmental, and respiratory problems. However, identifying pregnancies... Read more

Business

view channel
Image: Stryker has acquired ZuriMED, adding the FiberLocker System, a rotator cuff augmentation technology designed to strengthen repairs, to its Sports Medicine portfolio. (Photo courtesy of ZuriMED)

Stryker Completes Acquisition to Broaden Shoulder Surgery Offerings

Stryker (Portage, MI, USA) has completed its acquisition of ZuriMED (Zurich, Switzerland), a privately held developer of the FiberLocker System, expanding its Sports Medicine portfolio with a commercialized... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.