Intraoperative Nerve Imaging Makes Surgery Safer

By HospiMedica International staff writers
Posted on 30 Aug 2017
A new study describes how collimated polarized light imaging (cPLI) can aid real-time identification of nerves in the human hand.

Developed at Academic Medical Center (AMC, Amsterdam, The Netherlands) and Utrecht University (UU; The Netherlands), the long working-distance CPLi tool identifies peripheral radial nerve branches in a human hand by imaging nerve specific anisotropic optical reflection. More...
After first testing the technique on animal tissue, the researchers used it to examine 13 tissue sites from the hand of a human cadaver. A surgeon looked for nerve tissue at these sites under typical surgical illumination, while another surgeon used CPLi for assessment.

Histological evaluation was then used to verify the presence of nerve tissue at each site. The results showed that the surgeon using visual inspection correctly identified nerve tissue in 10 of the 13 cases (77%) while the surgeon using CPLi correctly identified nerve tissue in all cases (100% positive correct score). The technique will soon be tested during live surgery in order to better understand how the optical reflection of nerves might vary among patients under various surgical conditions. The study was published on August 16, 2017, in Biomedical Optics Express.

“We have shown that nerves can be distinguished in human tissue by detecting the interaction of light with the structure of nerves, without the need for fluorescent markers or physical interaction,” said lead author Kenneth Chin, a medical student at AMC. “Using an intraoperative, noninvasive real-time method minimizes potential nerve damage, which can result in fewer negative consequences such as reduced function, loss of sensation, or chronic pain.”

CPLi uses a collimated polarized beam of light to illuminate the tissue. When the parallel polarized light passes through a nerve, the tissue's unique internal structure reflects in a way that is dependent on how the nerve fiber is oriented, compared to the orientation of the polarization of the light. By rotating the polarization, the reflection appears to switch on and off, making the nerve tissue stand out from other tissue.

Related Links:
Academic Medical Center
Utrecht University

Gold Member
12-Channel ECG
CM1200B
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Medical Examination & Procedure Light
Vega 80
Patient Monitoring System
AlarmSense
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Anatomically guided sonography for trauma assessment includes a mixed reality headset (e.g., top left). Example views show virtual augmentation overlays for anatomy registration and ultrasound probe guidance on a test surrogate. The anatomical display is customized based on the organ or region being targeted with the ultrasound probe. (Robert S. Armiger, Anna E. Knight, Catherine M. Carneal, et al. Journal of Medical Imaging (2026). DOI: 10.1117/1.jmi.13.4.045001)

Anatomical Guidance System Improves Trauma Ultrasound Acquisition by Novice Users

Focused assessment with sonography for trauma (FAST) helps clinicians detect free fluid and signs of internal bleeding in injured patients, but obtaining reliable images can be difficult for inexperienced operators.... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.