DEXA Predicts Diabetes in Obese Menopausal Women

By HospiMedica International staff writers
Posted on 13 Sep 2021
Dual-energy x-ray absorptiometry (DEXA) beats traditional clinical obesity measures for predicting diabetes and heart disease in older women, according to a new study.

Researchers at Stanford University (CA, USA), the University of Illinois in Chicago (UIC; USA), and other institutions analyzed data on 9,744 postmenopausal women (50-79 years of age) who underwent a DEXA scan and were free of cardiovascular disease (CVD) and diabetes at baseline. More...
The aim of the study was to see if DEXA estimates of adiposity in older women could improve risk prediction for cardiometabolic diseases better than the traditional surrogates - body mass index (BMI), waist circumference (WC), and waist-to-hip ratio (WHR).

The results revealed a total of 1,327 diabetes, 1,266 atherosclerotic CVD, and 292 heart failure (HF) cases, as well as 1,811 deaths from any cause accrued during a median follow-up of 17.2 years. The largest hazard ratio per adiposity measure for diabetes and atherosclerotic CVD was percentage of trunk fat (%TrF), which was also the only adiposity measure to demonstrate statistically significant improved concordance probability estimates over BMI, WC, and WHR. The study was published on August 31, 2021, in Mayo Clinic Proceedings.

“The single most striking finding of our multivariable analyses was the magnitude of association observed between %TrF and the risk of incident diabetes,” concluded lead author Deepika Laddu, PhD, of the University of Chicago. “Using DEXA to improve risk prediction for cardiometabolic diseases among patients already being screened for osteoporosis presumably would have little impact on cost of care, and has the potential to impact public health substantially.”

DEXA is a means of measuring bone mineral density (BMD) using spectral imaging. Two X-ray beams, with different energy levels, are aimed at the bones. When soft tissue absorption is subtracted, BMD can be determined from the absorption of each beam. DEXA is most often used to diagnose and monitor osteoporosis.

Related Links:
Stanford University
University of Illinois in Chicago



Gold Member
12-Channel ECG
CM1200B
Hand-held Hemoglobin Analyzer
DiaSpect Tm
Monitor/Defibrillator
Zenix
Creatinine/eGFR Meter
StatSensor® Creatinine/eGFR Meter
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Critical Care

view channel
Image: Masimo smartSET pulse oximetry with PPG AFib and OIRD Detection (Photo courtesy of Masimo)

Smart Pulse Oximetry Supports Earlier Recognition of Arrhythmias and Respiratory Risk

On general care floors, respiratory compromise and arrhythmias can develop between routine checks. Atrial fibrillation often goes undiagnosed in older adults, while opioid-induced respiratory depression... Read more

Patient Care

view channel
Image: Researchers evaluated the Omni 128 cm long-axial field-of-view PET/CT system, which captures more of the body and radiotracer signal at once, potentially enabling shorter scans. (Photo courtesy of GE HealthCare)

Total-Body PET/CT Scanner Enables One-Minute Diagnostic-Quality Cancer Imaging

Positron emission tomography/computed tomography (PET/CT) combines radiotracer-based functional imaging with anatomical detail to diagnose, stage, and monitor cancer. Conventional scanners image the body... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: Steris is expanding its healthcare consumables portfolio through an agreement to acquire Xodus Medical, a surgical products business focused on patient and operating room staff safety.

Steris to Expand Surgical Safety Portfolio With $2.1 Billion Xodus Medical Deal

Steris has signed a definitive agreement to acquire Xodus Medical, a specialty surgical products business based in Pennsylvania, for $2.1 billion at closing. The acquisition will expand Steris’s healthcare... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.