Biodegradable Ultrasound Could Make Brain Cancers More Treatable

By HospiMedica International staff writers
Posted on 15 Jun 2023

When a person is found to have a malignant brain tumor, the usual treatment is surgical removal followed by chemotherapy to eradicate any remaining cancer cells. More...

However, brain cancers are notoriously resistant to chemotherapy, due to the blood-brain barrier, which is a protective membrane preventing large potentially harmful molecules from entering the brain. This same barrier also blocks beneficial chemo-drugs and other treatments from attacking brain cancer cells and treating other brain diseases. A safe and effective method of breaching the blood-brain barrier involves using ultrasound to vibrate cells sufficiently to create pores that allow the medication to pass through.

However, directing ultrasound through the thick human skull is challenging. Usually, numerous powerful ultrasound devices must be strategically positioned around the skull and accurately focused on the tumor's location with an MRI machine right after administering chemotherapy in a hospital setting. The procedure lasts about five to six hours and the intense ultrasound can damage tissues. The procedure is rarely conducted more than once, despite most patients with aggressive brain cancers undergoing chemotherapy for months. Utilizing ultrasound at each chemotherapy session would be significantly more effective. However, due to the complex nature of the MRI-ultrasound process, this is rarely done. Now, a revolutionary, biodegradable ultrasound, considerably more powerful than earlier models, could improve the treatment of brain cancers.

A device implanted directly in the brain can be used repeatedly to allow chemotherapy to permeate the brain and eliminate tumor cells. An implantable ultrasound device already exists in the market, but it's made of potentially toxic ceramic materials that require surgical removal post-treatment. Researchers at University of Connecticut (Storrs, CT, USA) had earlier built a safe, biodegradable piezoelectric ultrasound brain implant, although it wasn't as powerful as the traditional ceramic variants. In their latest research, the team employed a completely new method to create a biodegradable polymer ultrasound that is as powerful as ceramic models.

Initially, the researchers intended to use glycine crystals, an amino acid that's a common protein in the body and known for its strong piezoelectric properties. Glycine is safe and biodegradable, but it dissolves too quickly in water. Additionally, glycine piezoelectric crystals are brittle and shatter easily, which makes processing this material into a practical ultrasound device highly challenging. The researchers devised a unique solution: they grew glycine crystals, shattered them intentionally into pieces just a few hundred nanometers in size, and then spun them with polycaprolactone (PCL), a biodegradable polymer, to produce piezoelectric films composed of glycine and PCL nanofibers. These films can generate ultrasound at 334 kilo-Pascals under small voltage (~ 0.15 Vrms), similar to a ceramic ultrasound brain implant. They then coated the glycine-PCL film in other biodegradable polymers for protection. Poly-L-Lactide (PLLA), one potential coating, decomposes approximately in six weeks.

The researchers tested the device on mice with brain cancer, treating them with PTX (paclitaxel), a potent chemotherapy drug effective against brain cancer but difficult to pass through the blood-brain barrier. The glycine-PCL ultrasound successfully enabled PTX to cross the blood-brain barrier, reducing the tumors and doubling the lifespan of mice with brain cancer compared to those untreated. The combined treatment of glycine-PCL ultrasound and PTX was much more effective than using PTX alone, or PTX and ultrasound from the original, less powerful version of the biodegradable ultrasound device, based on PLLA. The team also conducted a six-month safety evaluation of the device implanted in the brain and found no negative impact on the health of the mice. The researchers now plan to test the safety and efficacy of the device in large animals.

Related Links:
University of Connecticut


Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Glucose Meter
StatStrip®
Fetal Monitor
BT-380
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: Adobe Stock

Noninvasive Imaging Approach Aims to Detect Basal Cell Carcinoma Before It Becomes Visible

Basal cell carcinoma is the most common form of skin cancer and can damage nearby structures such as the nose or eyes when it develops on the face. Diagnosis typically depends on visible skin changes,... Read more

Surgical Techniques

view channel
Image: Associate Professor Menglin Chen studies how the light-sensitive nanoparticles affect living cells. The screen shows calcium being released inside a cell after nanoparticles taken up by the cell are exposed to blue light. Calcium plays an important role in cellular signaling, and the experiment helps the researchers understand how the nanoparticles can translate light into biological activity. (Photo courtesy of Aarhus University, Johanne Holm Jensen)

Light-Activated Nanoparticles May Offer New Approach to Retinal Prostheses

Retinitis pigmentosa is a degenerative retinal disorder in which photoreceptors progressively die, reducing visual signals to the brain while leaving surviving inner retinal circuits underused.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.