Wearable Ultrasound Device Provides Long-Term, Wireless Muscle Monitoring

By HospiMedica International staff writers
Posted on 01 Nov 2024

Electromyography (EMG) is the current clinical standard for monitoring muscle activity, utilizing metal electrodes placed on the skin to capture electrical signals from muscles. More...

Despite its long-standing use, EMG faces challenges such as low resolution and weak signals. For instance, signals from multiple muscle fibers often blend, complicating the isolation of contributions from individual fibers. On the other hand, ultrasound offers high-resolution imaging that penetrates deep tissues, providing detailed insights into muscle function. Now, researchers have introduced a new wearable ultrasound technology for muscle monitoring that could serve as a promising alternative to EMG.

Engineers at the University of California San Diego (La Jolla, CA, USA) have created a wearable ultrasound device capable of long-term, wireless monitoring of muscle activity, with potential applications in healthcare and human-machine interfaces. The device is encased in flexible silicone elastomer and includes three main components: a single transducer for sending and receiving ultrasound waves, a custom-designed wireless circuit that controls the transducer, records data, and transmits it to a computer, and a lithium-polymer battery that provides power for at least three hours. Designed to adhere to the skin with an adhesive layer, the device allows for high-resolution tracking of muscle function without the need for invasive procedures. Additionally, the ultrasound technology is compact, wireless, and energy-efficient.

A significant innovation of this work is the utilization of a single ultrasound transducer to effectively sense deep tissues. This transducer emits intensity-controlled ultrasound waves and captures radiofrequency signals rich in information, enabling clinical applications such as measuring diaphragm thickness. By leveraging these signals, the device achieves high spatial resolution, which is essential for isolating specific muscle movements. To gain further insights from these signals, the researchers developed an artificial intelligence algorithm that maps the signals to their corresponding muscle distributions, allowing it to accurately identify specific hand gestures from the collected data.

In tests, the device was worn over the rib cage to monitor diaphragm motion and thickness, critical metrics for evaluating respiratory health. When worn on the rib cage, the device was able to measure diaphragm thickness with submillimeter precision. This measurement is clinically significant for assessing diaphragm dysfunction and predicting outcomes in ventilated patients. Additionally, by analyzing muscle motion, the researchers could differentiate between various breathing patterns, such as shallow versus deep breaths, which could aid in diagnosing conditions related to respiratory irregularities, including asthma, pneumonia, and chronic obstructive pulmonary disease (COPD). In a small trial, the device successfully distinguished the breathing patterns of individuals with COPD from those of healthy participants.

Furthermore, in research published in Nature Electronics, the team demonstrated the device's application on the forearm to capture hand and wrist muscle activity, enabling its use as a human-machine interface for controlling a robotic arm and playing a virtual game. When used on the forearm, the device precisely tracked muscle motion in the hands and wrists. Thanks to the artificial intelligence algorithm, the system can recognize various hand gestures based solely on ultrasound signals. It can identify 13 degrees of freedom, covering 10 finger joints and three wrist rotation angles, thus capturing even minor movements with high sensitivity. In proof-of-concept tests, participants controlled a robotic arm to pipette water into beakers and played a virtual game, steering a virtual bird through obstacles using wrist movements. Going forward, the researchers aim to enhance the technology’s accuracy, portability, energy efficiency, and computational capabilities.

 


Gold Member
Handheld Blood Glucose Analyzer
STAT-Site
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Hypodermic Syringe
SurTract™ Safety Syringe
Medical-Grade Display
HL2316SHTB
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image Credit: Adobe Stock

Emergency Department Campaign Reduces CT Use Without Identified Missed Injuries

Unnecessary head and cervical spine computed tomography (CT) in low-risk trauma patients exposes them to avoidable radiation, prolongs emergency department stays, and increases healthcare costs.... Read more

Surgical Techniques

view channel
Image: Researchers developed a handheld photothermal mid-infrared spectroscopic imaging (MIRSI) system that measures just 8 square inches. Probe light from a visible (red) diode laser and pump light from a modulated quantum cascade laser (QCL) are coupled into optical fibers and delivered to a flexible, handheld imager (blue dashed box). The beams are combined at a short-pass dichroic mirror and focused onto the sample using an off-axis parabolic mirror (OAP). (Image Credit:Rohith Reddy, University of Houston)

Handheld Infrared Imaging Device Supports Tumor Margin Assessment During Surgery

Accurately determining tumor margins during surgery remains challenging. Frozen-section pathology takes time and can miss residual disease, potentially leading to repeat surgery and delayed therapy.... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.