Thyroidectomy Bed Drainage Timing Is Volume-Dependent

By HospiMedica International staff writers
Posted on 20 Jan 2014
Surgical drains can be removed following thyroid surgery once the volume of the fluid drained is reduced and is clear, according to a new study. More...


Researchers at the Nagasaki University Graduate School of Biomedical Sciences (Japan) conducted a retrospective study of 249 patients who underwent thyroid surgery, in order to evaluate the chronological changes in the amount of drainage fluid and to establish standard indications for the drain to be removed. The patients were divided into four groups: a Graves’ group, a non-dissection group, a central-dissection group, and a lateral-dissection group. The amount of drainage was measured every 6 hours, and the drain was removed postoperatively when the drainage decreased in amount and contained serous fluid after a meal.

The results showed that in all four groups, the most drainage occurred in the first six hours after surgery. The total amount of drainage from the operation to the time of drain removal was significantly higher in Graves’ group and in the lateral-dissection group than in the other two groups. The median wound drainage significantly decreased from 12–18 hours after surgery in all four groups. In the lateral-dissection group, the wound drainage significantly decreased again in the first 24–30 hours. The study was published in the January 2014 issue of Surgery Today.

“The findings of this study suggest that drains can be removed postoperatively if the drainage was less than 15 mL during a 6-hour period, and contain serous fluid,” concluded lead author Shigeki Minami, MD, PhD, and colleagues of the department of surgery and the department of global health, medicine and welfare.

Although drainage of the thyroidectomy bed is not an evidenced-based practice, most surgeons still employ routine drainage with an effort to monitor postoperative bleeding. Several studies, however, have indicated that not only is it not effective in decreasing the rate of postoperative complications after thyroid surgery, it actually causes a prolonged hospital stay and may lead to surgical site infection (SSI).

Related Links:

Nagasaki University Graduate School of Biomedical Sciences



Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Ultrasound Needle Guidance System
SonoSite L25
VTE Prevention System
Flowtron ACS900
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Patient Care

view channel
Image: The revolutionary automatic IV-Line flushing device set for launch in the EU and US in 2026 (Photo courtesy of Droplet IV)

Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care

More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read more

Business

view channel
Image: The collaboration will integrate Masimo’s innovations into Philips’ multi-parameter monitoring platforms (Photo courtesy of Royal Philips)

Philips and Masimo Partner to Advance Patient Monitoring Measurement Technologies

Royal Philips (Amsterdam, Netherlands) and Masimo (Irvine, California, USA) have renewed their multi-year strategic collaboration, combining Philips’ expertise in patient monitoring with Masimo’s noninvasive... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.