Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Werfen

Download Mobile App




Infant’s Cardiac Valve Replaced Through the Liver

By HospiMedica International staff writers
Posted on 30 Nov 2014
A novel surgical procedure successfully placed a tricuspid valve in a one-year-old infant using a catheter through the liver, since infants’ blood vessels are too small to transport it to the heart. More...


Pediatric cardiologists at University Hospitals Leuven (UZ Leuven, Belgium) previously replaced the tricuspid cardiac valve in the child just after birth, via an open-heart procedure. However, the valve was quickly broken down due to the infants’ immune defenses, and after just one year, the patient needed a new valve. A further complication was that the specific cardiac valve required for the intervention was only available in a larger standard format, which made it necessary to trim it down to fit the patient.

The surgeons claim that the liver is a good alternative for catheterization because it acts like a sponge, is relatively easy to perforate, and is made up of large sheaths of tissue. However, there are risks involved, since the opening must be well-sealed after the intervention to prevent potentially fatal bleeding. The surgical team therefore included both a liver surgeon and a cardiac surgeon who remained in standby in the event that the catheterization technique failed and open-heart surgery became necessary.

“Any further open-heart surgery would entail severe health risks and follow-up procedures, so we opted for a percutaneous intervention via a catheter,” says cardiologist Prof. Marc Gewillig, MD, PhD, head of pediatric cardiology at UZ Leuven. “Normally we would put a catheter through a vein in the neck or groin to the heart. But in children who weigh less than ten kilograms, these blood vessels are too small for such a catheter, which is 7 to 8 millimeters wide. That is why we used an alternative access point through the liver.”

The hepatic veins drain de-oxygenated blood from the liver and blood cleaned by the liver (from the stomach, pancreas, small intestine and colon) into the inferior vena cava. They arise from the substance of the liver, more specifically from the central vein of a liver lobule; none of the hepatic veins have valves. The upper groups of veins typically arise from the posterior aspect of the liver, and are larger than the lower veins.

Related Links:

University Hospitals Leuven



Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Floor‑Mounted Digital X‑Ray System
MasteRad MX30+
LED Surgical Lamp
ACEMST35/57
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Patient Care

view channel
Image: The revolutionary automatic IV-Line flushing device set for launch in the EU and US in 2026 (Photo courtesy of Droplet IV)

Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care

More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read more

Business

view channel
Image: The collaboration will integrate Masimo’s innovations into Philips’ multi-parameter monitoring platforms (Photo courtesy of Royal Philips)

Philips and Masimo Partner to Advance Patient Monitoring Measurement Technologies

Royal Philips (Amsterdam, Netherlands) and Masimo (Irvine, California, USA) have renewed their multi-year strategic collaboration, combining Philips’ expertise in patient monitoring with Masimo’s noninvasive... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.