New Stent Graft Design Improves Blood Flow

By HospiMedica International staff writers
Posted on 09 Sep 2015
A novel branching stent graft that can be deployed from the top on down could help patients suffering from thoracoabdominal aortic aneurysms (TAAAs).

Developed by researchers at Sanford Health (Sioux Falls, SD, USA) and South Dakota State University (SD State; Brookings, SD, USA) under an exclusive patent license agreement with Medtronic (Dublin, Ireland), the TAAA Debranching Stent Graft System is comprised of a thoracic bifurcation and visceral manifold graft, which work together to facilitate endovascular stenting of the visceral vessels—the renal, celiac, and superior mesenteric arteries—while maintaining blood flow to the visceral and infrarenal segments. More...


The complexity of the design required the use of computational fluid dynamics (CFD) simulations, conducted at SD State, in order to create a geometrically correct model of each graft relative to the same aorta coordinates and positioning in the body trunk, as well as the arteries that feed the organs and extend into the legs. To model blood flow near the artery walls (where atherosclerosis tends to begin), the researchers had to consider oscillating shear index, time-averaged wall shear stress, relative residence time, and wall shear stress temporal gradient.

To account for the transient pulsatile flow of blood, an extensive data table was entered into the software specifying the volumetric flow rate of blood through the system every 1/5,000 of a second, outputing a solution every 1/1,000 of a second to simulate a one-second cycle. The CFD simulations helped the researchers show that flow behavior next to the artery wall is more ordered, predictable, and moderate with the new stent design, splitting the blood flow upstream and letting it gradually come to the renal arteries. A study describing the system and the procedure were published in the November 2014 issue of the Journal of Vascular Surgery.

“Taking the complex and making it simple has long been our goal for the treatment of TAAAs. Working with Medtronic could eventually place our solution in the hands of vascular surgeons around the world to help patients facing a life-threatening condition,” said Sanford Health vascular surgeon Patrick Kelly, MD, who developed the concept. “We hope that this will have a major impact on the treatment of one of the most challenging disease processes to face our specialty.”

Degradation of structural proteins such as collagen and elastin, or a defect in their composition, leads to medial degeneration and weakening of the aortic wall. TAAA then results from a continuous dilation of the descending thoracic aorta, extending into the abdominal aorta. Subsequent dilatation results from hemodynamic forces on the arterial wall, as well as intrinsic changes in the composition of the arterial wall itself, which cause the diameter of the aorta to expand further and increase wall tension, thus creating a vicious cycle.

Medtronic plans to study the system in collaboration with physicians at several medical centers, including Dr. Kelly at Sanford Health, starting in the near future, with the purpose of subsequently commercializing the system after obtaining the required regulatory approvals.

Related Links:

Sanford Health
South Dakota State University
Medtronic



Gold Member
Neonatal Heel Incision Device
Tenderfoot
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
Creatinine/eGFR Meter
StatSensor® Creatinine/eGFR Meter
Hybrid Arch Device
Neo EDE
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie MellonImage: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie Mellon University)University)

Portable Artificial Lung Technology Could Reshape Care for Chronic Lung Disease

Chronic lung disease can leave patients dependent on prolonged mechanical ventilation or awaiting transplantation, both of which carry substantial morbidity and healthcare costs. Ventilatory support may... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.