Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Novel Application Instantly Confirms Spinal Implant Placement

By HospiMedica International staff writers
Posted on 20 Jun 2012
A new software application allows for quick verification of spinal implant placement, and reduces the potential for revision cases due to misplaced pedicle screws.

The Renaissance C-OnSite software application can be used with any commonly found two-dimensional (2D) C-Arms, which are standard equipment in spine operating rooms. More...
Rotating the C-arm for 15 seconds around the implant site provides sufficient data to create a three-dimensional (3D) reconstruction, from which measurements can be made and the overall procedure analyzed. If issues are discovered, corrective steps can be taken immediately, rather than as a revision case a few days later. The process requires no more than 5 to 10 minutes of additional OR time.

The 15-second C-Arm rotation scan is performed after screw positioning, and the images are fused with high-quality images from the preoperative computerized tomography (CT). This produces an intraoperative 3D axial view of the spine, showing the exact location of each pedicle screw and its relationship to the spinal canal, without additional, expensive intra-operative 3D systems for spine surgery. The Renaissance C-OnSite software application is a product of Mazor Robotics (Caesarea, Israel), and has already been incorporated into the company’s Renaissance surgical guidance system.

“Renaissance C-OnSite combines the enhanced accuracy of robotic guidance with actionable, intraoperative 3D image-based verification of screw positioning for immediate evaluation and correction,” said Ori Hadomi, CEO of Mazor Robotics. “By delivering post-op information during the surgical procedure, C-OnSite makes Renaissance a full solution for the spine surgeon, from pre-op planning through surgical guidance to verification.”

“The patient gets the equivalent of a post-op CT before leaving the operating room without the high radiation levels, and does not have to wait to rule out the need for revision surgery,” said Payam Moazzaz, MD, an orthopedic spine surgeon at TriCity Medical Center (Oceanside, CA, USA).

Currently, the most common way to accurately verify the placement of pedicle screws is by postoperative CT. But since it takes place after the surgery has been completed, significant misplacements necessitate a revision surgery. Intraoperative imaging systems are usually 2D, which is not sensitive enough for verification purposes, and 3D systems are not very common and are very expensive.

Related Links:

Mazor Robotics
TriCity Medical Center



Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
Radiology Monitor
MDNC-6121 Barco Nio Color 5.8MP
POC Respiratory/Sore Throat Test
BIOFIRE SPOTFIRE (R/ST) Panel
Digital Radiography System (Ceiling Free)
Digix CF Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Artificial Intelligence

view channel
Image: Artificial intelligence (AI) standalone performance and reader performance with versus without AI assistance. (A) Receiver operating characteristics (ROC) curve for AI standalone performance in the US dataset (AUC 0.899, 95% CI 0.858 to 0.939). (B) ROC curve for AI standalone performance in the Korean dataset (AUC 0.963, 95% CI 0.946 to 0.975). (C) Pooled reader ROC without (AUC 0.718) versus with (AUC 0.852) AI assistance in the Korean dataset; P<0.001. AUC, area under the receiver operating characteristics curve. (Leonard Sunwoo et al., Journal of NeuroInterventional Surgery (2026). DOI: 10.1136/jnis-2026-025339)

AI Improves Non-Contrast CT Interpretation for Time-Sensitive Stroke Assessment

Acute ischemic stroke occurs when a blood vessel in the brain becomes blocked, requiring rapid diagnosis to enable timely reperfusion therapy. Emergency departments often use computed tomography angiography... Read more

Critical Care

view channel
Image: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie MellonImage: Tubes attached to this artificial lung are connected to the patient\'s neck or chest, allowing blood to circulate and get oxygen while the patient is conscious. (Image Credit: Carnegie Mellon University)University)

Portable Artificial Lung Technology Could Reshape Care for Chronic Lung Disease

Chronic lung disease can leave patients dependent on prolonged mechanical ventilation or awaiting transplantation, both of which carry substantial morbidity and healthcare costs. Ventilatory support may... Read more

Point of Care

view channel
Image Credit: 123RF

Continuous Glucose Monitoring Identifies Cardiometabolic Risk in Adults Without Diabetes

Dysglycemia—abnormal blood glucose regulation—can fluctuate throughout the day and often escape conventional screening. Clinicians typically rely on fasting plasma glucose and hemoglobin A1c, which offer... Read more

Business

view channel
Image: LigaSure RAS Maryland, designed for the Valleylab FT10 platform on Hugo RAS, seals and cuts vessels, tissue, and lymphatics up to 7 mm in diameter (Photo courtesy of Medtronic)

Medtronic Receives FDA Clearance for Vessel-Sealing Instrument for Robotic Surgery

As robotic-assisted surgery expands across U.S. hospitals, teams increasingly seek energy instruments with the familiarity and performance of tools used in open and laparoscopic procedures.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.