Handheld Device Uses Fiber Optic Sensor to Determine Correct Nasogastric Feeding Tube Placement

By HospiMedica International staff writers
Posted on 17 Jul 2023
Print article
Image: The NGPod device is designed for correct placement of nasogastric tubes (Photo courtesy of NGPod Global)
Image: The NGPod device is designed for correct placement of nasogastric tubes (Photo courtesy of NGPod Global)

Annually, nurses are tasked with inserting over a million feeding tubes into patients' stomachs for the delivery of nutrition, hydration, and medication. It is reported that inaccurate placement of nasogastric tubes (NGTs) occurs in 1-3% of all insertions, which can lead to severe consequences including treatment delays and, in some cases, death. The majority of NGTs are inserted 'blind', as the procedure does not involve any form of visualization to confirm correct positioning before use. Traditional methods, in use for the past 20 years, are inherently flawed. The first technique to confirm NGT placement involves pH testing of the NGT aspirate. If a pH level of 5.5 or lower is achieved, the NGT is deemed safe, otherwise, chest X-rays are required. However, pH strips can fail in up to 45% of cases due to difficulty in obtaining aspirate, necessitating an X-ray for the patient and causing an average treatment delay of approximately eight hours. Now, a new electronic device specifically designed for correct NGT placement could eliminate the problem of incorrectly inserted feeding tubes.

NGPod Global (Cheshire, UK) has developed the NGPOD system, a device designed to tackle the risks associated with traditional nasogastric placement confirmation techniques. The portable NGPod device employs a fiber optic sensor that is introduced directly into the stomach via the feeding tube, eliminating the need for aspirate while transmitting light signals back to a handheld device. The NGPOD system also eliminates the need to aspirate gastric contents from the patient and reduces the risk of clinical interpretation errors by providing a safe bedside test that delivers a clear 'yes' or 'no' result. Furthermore, the device lowers the requirement for unnecessary X-rays to confirm placement, contributing to patient safety and cost-efficiency.

Using the product is straightforward and would require a maximum of 20 minutes for a professional to learn how to use the device with barriers set up in the device to prevent human errors. In a recent clinical trial consisting of 154 adult patients, researchers compared the performance of NGPod against the current pH strip procedures and found that it reduces the need for patients to use an X-ray by 61% while improving safety and human error. The device is currently in 12 hospitals in the UK with another eight scheduled to be implemented in the next six months.

Related Links:
NGPod Global 

Gold Member
12-Channel ECG
CM1200B
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Illuminated Retractor System
HandLite

Print article

Channels

Surgical Techniques

view channel
Image: The device\'s LEDs light up in several colors, allowing surgeons to see which areas they need to operate on (Photo courtesy of UC San Diego)

Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons

During brain surgery, neurosurgeons need to identify and preserve regions responsible for critical functions while removing harmful tissue. Traditionally, neurosurgeons rely on a team of electrophysiologists,... Read more

Patient Care

view channel
Image: The newly-launched solution can transform operating room scheduling and boost utilization rates (Photo courtesy of Fujitsu)

Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization

An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.