MDCT Radiation Dose Can Be Reduced by the Use of Pediatric Breast Shields

By MedImaging staff writers
Posted on 26 Feb 2008
Using breast shields during pediatric chest multi-detector computed tomography (MDCT) imaging reduces radiation dose and minimally increases image noise, according to a recent study.

The study was conducted by researchers at Duke University Medical Center (Durham, NC, USA) and the University of Arkansas for Medical Sciences and Arkansas Children's Hospital (Little Rock, USA).

"It's important for radiologists to limit dose in CT, especially to children, and especially to radiosensitive regions, such as breast tissue; and radiologists should be familiar with strategies to do this,” said Donald P. More...
Frush, M.D., lead author of the study. "Two strategies are breast shielding, and the other is automatic tube current modulation [ATCM]. However, the combination of the shield and ATCM may not be effective since the equipment might increase the dose to penetrate the shield. We wanted to see if there was a way to circumvent this, and in fact, there was: by placing the shields on the patient after the topogram [scout] from which the tube current would be modulated. This was tested using a GE [Healthcare] scanner [Chalfont St. Giles, UK] and it may not work with other scanners.”

Researchers performed MDCT on the chest an anthropomorphic phantom that represented a five-year-old child. They obtained two scans in each of four sequences: without the shield, with a two-ply bismuth shield, ATCM after placement of the shield, and ATCM before placement of the shield.

The study revealed that the bismuth breast shield reduced radiation dose to the breast by 26%, and shielding and ATCM reduced the dose by 52%. The study also showed that multiple organ doses were lowest when the shield was placed after the scout radiograph was obtained. With this technique, image noise increased, but the images were still of good quality.

"Radiologists need to understand their equipment's ATCM before using shielding. Parents should inquire about dose reduction strategies before their child undergoes a CT scan, and physicians who refer pediatric patients to radiologists should understand that research is continuing to minimize radiation dose in CT,” said Dr. Frush.

The full results of this study appear in the January 2008 issue of the American Journal of Roentgenology.


Related Links:
Duke University Medical Center
Arkansas Children's Hospital

Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Radiation Safety Barrier
RayShield Intensi-Barrier
Open Stapler
PROXIMATE Linear Cutter
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to HospiMedica.com and get access to news and events that shape the world of Hospital Medicine.
  • Free digital version edition of HospiMedica International sent by email on regular basis
  • Free print version of HospiMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of HospiMedica International in digital format
  • Free HospiMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Patient Care

view channel
Image: The revolutionary automatic IV-Line flushing device set for launch in the EU and US in 2026 (Photo courtesy of Droplet IV)

Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care

More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read more

Business

view channel
Image: The collaboration will integrate Masimo’s innovations into Philips’ multi-parameter monitoring platforms (Photo courtesy of Royal Philips)

Philips and Masimo Partner to Advance Patient Monitoring Measurement Technologies

Royal Philips (Amsterdam, Netherlands) and Masimo (Irvine, California, USA) have renewed their multi-year strategic collaboration, combining Philips’ expertise in patient monitoring with Masimo’s noninvasive... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.